-
Features The M92 is a melt pressure and temperature monitoring system which comes complete with the following items: • M32-6-M-xxxx-1-4-D-000 (melt pressure transducer with type “J” thermocouple) • 40TB-10-RRR-2-0-1 (1/4 DIN pressure and temperature indicator) • C08WLS (25 foot 6-pin cable) • SF18 (mounting bracket)
-
Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • The grooves on the profile provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses with installation at points that are highly exposed to lubricants • Also indicated for processing machines on which the transducer cannot be protected by guards
-
Features • The transducer has been improved in order to guarantee greater reliability under all conditions • A sturdier structure makes the LT series even stronger for applications with heavy vibration • Installation is made simpler by the absence of electrical signal variation in output, outside the Theoretical Electrical Stroke • The new grooves provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses, vertical presses, and on many other processing machines
-
Features • Ranges: from 1 to 1000 bar • Nominal Output Signal: 4...20mA (2 wires) 0...10Vdc / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc / 1...5Vdc / 1...6Vdc / 1...10Vdc / 0.2...10.2Vdc (3 wires) 0.5...4.5Vdc (3 wires - ratiometric) • Compact size • Wetted parts: Stainless steel • SIL 2 certified according to IEC/EN 62061:2005
-
Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: KN0 series (30mm3) [0.00183 in3], KN1, KN2, KN3 (40mm3) [0.00244 in3] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • SIL2 approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
-
Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
-
Features Electrical • Digital output signal with DP404 CAN OPEN communication protocol • Transmission frequency (Baud rate): 10 Kbaud to 1Mbaud (default 500 Kbaud) • Software selection of Baud rate and ID nodes • Operation with 1 or 2 settable alarm limits • “Autozero” for temperature compensation • 80% FSO calibration signal
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • SIL2 approvals for Functional Safety • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
-
Features • Pressure ranges from: 0-17 ato 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: K70 series (30mm³) [0.00183 in³], K71, K72, K73 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
-
Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy <±0.25% FSO (H); <±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS • Quantity of NaK contained per model: K30 series (30mm³) [0.00183 in³], K31-K32-K33 series (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • “Mercury free” hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH • IO-Link output, ready for “Industry 4.0” • Rangeabilty: 3:1 • PLd and SIL2 approvals for Functional safety • Autozero function • Auxiliary information over IO-Link protocol
-
Features • ONDA technology • Stroke: 50 to 4000mm • Position resolution settable via software up to 1 μm • Speed resolution up to 0.25 mm/sec • Conforms to CE directives (EN 50081-1 50082-1) • Vibration-resistant (DIN IEC68T2/6 12 g) • IP67 protection rating • Controls up to four cursors simultaneously • Two M12 connectors for simplified connection to Profibus and one M8 connector for separate connection to power supply (transducer can be powered without having to be connected to bus) • Local intelligence • Profibus DPV0 interface on RS485 in conformity to IEC 61158
-
Principal Characteristics • Transducer with exposed tracks, allowing rod diameter is reduced to be reduced to a minimum to permit installation in small cylinders. • Thanks to a special constructive technique, the IC transducer provides high resistance to the working pressures of oil-pressure cylinders (max 340 bar) • Available with internal flanges or external threads to guarantee mechanical compatibility with all principal cylinder types.
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • SIL2 and PL d approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi (up to 400°C/750°F) • Stem material: 17-4 PH
-
Features • Command input from analogue voltage or current signal or potentiometer. • Switching at voltage zero crossing. • Partialization of wave train power with dynamically optimized time cycle. • Antiparallel double SCR • 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm • 4000V isolation between input circuit and power output • MOV (varistor) • Optional monitoring of interrupted load • DIN rail mounting (standard); Panel mounting (optional)
-
Features • Command input from analogue voltage or current signal or potentiometer. • Switching at voltage zero crossing. • Partialization of wave train power with dynamically optimized time cycle. • Antiparallel double SCR • 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm • 4000V isolation between input circuit and power output • MOV (varistor) • Optional monitoring of interrupted load
-
Features • Command input from analogue voltage or current signal or potentiometer. • Switching at voltage zero crossing. • Partialization of wave train power with dynamically optimized time cycle. • Antiparallel double SCR • 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm • 4000V isolation between input circuit and power output • MOV (varistor) • Optional monitoring of interrupted load
-
Features • Measurement range: ±180° - different values on request programmable in steps of ±15° (ONLY for analogue versions) • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +9…+36Vdc (see output signal for right supply voltage) • Output signal: 0.5...4.5V RATIOMETRIC (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen, SAE J1939 • Electrical connections: AMP Superseal 6P 282108-1; cable output 18 AWG 1.65mm OD • Resolution and speed of rotation: 12 bit (analog output); 14 bit (CANopen/SAE J1939 output); 120 rpm max. • Linearity: < ±0.5%FS • Working and coefficient temperature: -40°C ... +85°C (higher values on request); thermal drift < 50 ppm/°C
-
Features • Measurement range: ±180° different values on request programmable in steps of ±15° (ONLY for analogue versions) • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +9…+36Vdc (see output signal for right supply voltage) • Output signal : 0.5...4.5V Ratiometric (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen, SAE J1939 • Electrical connections: AMP Superseal 6P 282108-1; DEUTSCH 6P DT04-6P • Resolution and speed of rotation: 12 bit (analog output); 14 bit (CANopen/SAE J1939 output); 120 rpm max. • Linearity: < ± 0.5% FS • Working and coefficient temperature: -40°C ... +85°C (higher values on request); thermal drift < 50 ppm/°C
-
Features • Alternating current solid state relay • Zero crossing switching • 15, 25, 50, 75 e 90 Arms nominal current • Non-repetitive voltage: up to 1600Vp • Nominal Voltage: up to 600 Vac • Control voltage : 3...32Vcc and 20...260Vac/ Vcc with connector • Isolation ((input-output) 4000Vrms • Green LED drive active signal