  • Principal Characteristics • The transducer is designed to satisfy extreme applicative demands in terms of mechanical strength. • The 10 mm diameter rod, large steel joints, and reinforced structure make this series mechanically ideal for Metal working, woodworking, and ceramics. • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • The structure based on self-aligning and weight-bearing ball joints permits assembly with free movement of the transducer axle
  • Features
    • Independent adjustment of Max and BIAS.
    • Down-opened Panel, easy for fuse replacement.
    • VR of Max and SFS are installed in the front panel, easy for adjustment.
    • Multi-LED display panel makes the operating condition clear.
    • The auxiliary powers (AC1, AC2) are independently controlled for all models.
    • Build-in buffering output adjustment (SFS VR), adjusting range 1~22 seconds. (Only for the phase control product)
    • Top & bottom shielding covers are designed for safety and fashion out looking, also easy for wiring installation.
    • In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse burn-down
  • Features • Current sizes 16, 32, 40 Amps per channel • Integrated current transformers • Fuses with fuse-holder disconnectors on the front (option) • 4 universal process inputs ( TC, RTD, mA, V ) • 4 independent hot/cold PIDs • 4 main outputs (directly connected to the static unit) • 4 auxiliary analogue inputs (option) • 4 settable outputs (option): relay/logic/TRIAC/analogue • 2 settable relay outputs • 2 settable digital inputs • Modbus RTU communication port • Communication port for Fieldbus (option): Profinet, Profibus DP, Ethernet IP, EtherCAT, Modbus TCP/RTU, CANopen, DeviceNET • ODVA (Ethernet/IP) and PI (ProfiNET) certification • DIN rail or panel mounting • CE, UL, CSA certifications and SCCR UL 508 100KA approval
  • Features • 4 independent loop control unit. compact, ready to use, equipped also with fieldbus interface.
  • Features • Command input from analogue voltage or current signal or potentiometer. • Switching at voltage zero crossing. • Partialization of wave train power with dynamically optimized time cycle. • Antiparallel double SCR • 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm • 4000V isolation between input circuit and power output • MOV (varistor) • Optional monitoring of interrupted load • DIN rail mounting (standard); Panel mounting (optional)
  • Features • Alternating current solid state relay • Zero crossing switching • 15, 25, 50, 75 e 90 Arms nominal current • Non-repetitive voltage: up to 1600Vp • Nominal Voltage: up to 600 Vac • Control voltage : 3...32Vcc and 20...260Vac/ Vcc with connector • Isolation ((input-output) 4000Vrms • Green LED drive active signal
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • SIL2 and PL d approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi (up to 400°C/750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • “Mercury free” hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH • IO-Link output, ready for “Industry 4.0” • Rangeabilty: 3:1 • PLd and SIL2 approvals for Functional safety • Autozero function • Auxiliary information over IO-Link protocol
  • Features • Pressure ranges from: 0-17 ato 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: K70 series (30mm³) [0.00183 in³], K71, K72, K73 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • SIL2 approvals for Functional Safety • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • SIL2 approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features Electrical • Digital output signal with DP404 CAN OPEN communication protocol • Transmission frequency (Baud rate): 10 Kbaud to 1Mbaud (default 500 Kbaud) • Software selection of Baud rate and ID nodes • Operation with 1 or 2 settable alarm limits • “Autozero” for temperature compensation • 80% FSO calibration signal
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: KN0 series (30mm3) [0.00183 in3], KN1, KN2, KN3 (40mm3) [0.00244 in3] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy <±0.25% FSO (H); <±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS • Quantity of NaK contained per model: K30 series (30mm³) [0.00183 in³], K31-K32-K33 series (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Ranges 1800mm, 2300mm, 3300mm ……… 8300mm • Linearity 0.5% and repeatability 0.1% • Working temperature -40 to 85C • Life cycles 250000 (potientiometer) • Power 10-30VDC
  • Features • Ranges +/- 10,15,30,45,60,85 and 180 degrees • Accuracy from 0.15% to 0.5% in different models • Output 0-10V, 0.5-4.5V ratiometric, 4-20mA or CANopen • Environmental rating IP67 or better for cable entry • Compact size and rated to 85C
  • Features
    • Measurement range : ±10° ±15° ±20° ±30° ±45° ±60° ±85° (dual axis XY); 360° (±180°) (single axis Z)
    • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +10…+36Vdc (see output signal for right supply voltage)
    • Output signal: 0.5...4.5V RATIOMETRIC (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen
    • Electrical connections: AMP Superseal 6P 282108-1; 6 wires output 18 AWG 1.65mm OD (cable+connector on request)
    • Resolution: 0.05° (±10° to ±20°); 0.05°(±30°); 0.1°(±45°); 0.1°(±60°); 0.1°(±85°); 0.1° (±180°) analog output; 0.05° CANopen output
  • Features • Measurement range: ±180° - different values on request programmable in steps of ±15° (ONLY for analogue versions) • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +9…+36Vdc (see output signal for right supply voltage) • Output signal: 0.5...4.5V RATIOMETRIC (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen, SAE J1939 • Electrical connections: AMP Superseal 6P 282108-1; cable output 18 AWG 1.65mm OD • Resolution and speed of rotation: 12 bit (analog output); 14 bit (CANopen/SAE J1939 output); 120 rpm max. • Linearity: < ±0.5%FS • Working and coefficient temperature: -40°C ... +85°C (higher values on request); thermal drift < 50 ppm/°C
  • Features • Measurement range: ±180° different values on request programmable in steps of ±15° (ONLY for analogue versions) • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +9…+36Vdc (see output signal for right supply voltage) • Output signal : 0.5...4.5V Ratiometric (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen, SAE J1939 • Electrical connections: AMP Superseal 6P 282108-1; DEUTSCH 6P DT04-6P • Resolution and speed of rotation: 12 bit (analog output); 14 bit (CANopen/SAE J1939 output); 120 rpm max. • Linearity: < ± 0.5% FS • Working and coefficient temperature: -40°C ... +85°C (higher values on request); thermal drift < 50 ppm/°C
  • Features • The transducer has been improved in order to guarantee greater reliability under all conditions • A sturdier structure makes the LT series even stronger for applications with heavy vibration • Installation is made simpler by the absence of electrical signal variation in output, outside the Theoretical Electrical Stroke • The new grooves provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses, vertical presses, and on many other processing machines
  • Features • Absolute transducer • Stroke: 50 to 2500mm • Direct analog output (RK-5 N/K/E) • Inverse analog output (RK-5 O/I/R) • Operating temperature: -40...+105°C • Vibration-resistant (DIN IEC68T2/6 25g) • Power range 10VDC...32VDC current output • Power range 8VDC...32VDC voltage output
  • Main Characteristics • Absolute transducer • Strokes from 50 to 4000mm (RK-4-_ _ _ _ -N/E/R) • Direct analog output (RK-4-_ _ _ _ -N/K/E) • Reverse analog output (RK-4-_ _ _ _ -R) • Operating temperature: -30...+90°C • Resistance to vibration (DIN IEC68T2/6 20g) • Power supply 18Vdc...30Vdc • Optional 12Vdc power supply (RK-4-_ _ _ _ -K)
  • Main Characteristics • Absolute transducer • Strokes from 50 to 4000mm (RK-2-_ _ _ _ -N/E/S) • Digital output RS422 Start/Stop (RK-2-_ _ _ _ -S) • Direct analog output (RK-2-_ _ _ _ -N/K/E) • Operating temperature: -30...+90°C • Resistance to vibration (DIN IEC68T2/6 20g) • Power supply 18Vdc...30Vdc • Optional 12Vdc power supply (RK-2-_ _ _ _ -K) • The digital version (RK-2-_ _ _ _ -S) allows the remote connection (max. 50 m) of optional electronics for use of advanced analog (EKA)
  • Features • ONDA technology • Stroke: 50 to 4000mm • Position resolution settable via software up to 1 μm • Speed resolution up to 0.25 mm/sec • Conforms to CE directives (EN 50081-1 50082-1) • Vibration-resistant (DIN IEC68T2/6 12 g) • IP67 protection rating • Controls up to four cursors simultaneously • Two M12 connectors for simplified connection to Profibus and one M8 connector for separate connection to power supply (transducer can be powered without having to be connected to bus) • Local intelligence • Profibus DPV0 interface on RS485 in conformity to IEC 61158
  • Main Characteristics • Optimized mechanical structure • Strokes from 50 to 4000 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Power supply 10....32 Vdc • Resistance to vibration (DIN IEC68T2/6 15g) • Protection IP67 • Work temperature: -30°…+90°C • Synchronous Serial Interface direct to controllers • Output data resolution available from 0.5 to 40μm • Data format: binary or Gray code; incremental/decremental • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimized mechanical structure • Strokes from 50 to 2500 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Power supply 10....32 Vdc • Resistance to vibration (DIN IEC68T2/6 12g) • Protection IP67 • Work temperature: -30°…+90°C • Synchronous Serial Interface direct to controllers • Output data resolution available from 20 to 40μm • Data format: binary or Gray code; incremental/decremental • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimized mechanical structure • Strokes from 50 to 4000 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Work temperature: -30°…+85°C • Resistance to vibrations (DIN IEC68T2/6 15g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimized mechanical structure • Strokes from 50 to 2500 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Work temperature: -30°…+75°C • Resistance to vibrations (DIN IEC68T2/6 12g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Magnetostrictive technology • Strokes from 50 to 1500 mm • Optimized mechanical structure • Rod, nipple, exagonal flange AISI 316 • Work temperature: -20....+75°C • Resistance to vibrations (DIN IEC68T2/6 12g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Features • ONDA technology • Stroke: 50 to 4000mm • Position resolution settable via software up to 1 μm • Speed resolution up to 0.25 mm/sec • Conforms to CE directives (EN 50081-1 50082-1) • Vibration-resistant (DIN IEC68T2/6 12 g) • IP67 protection rating • Controls up to four cursors simultaneously • Two M12 connectors for simplified connection to Profibus and one M8 connector for separate connection to power supply (transducer can be powered without having to be connected to bus) • Local intelligence • Profibus DPV0 interface on RS485 in conformity to IEC 61158
  • Main Characteristics • Optimised mechanical structure • Strokes from 50 to 4000 mm • Fast installation by mean of steel brackets • Sliding or floating magnetic cursor • Synchronous Serial Interface direct to controllers • Output data resolution available from 0.5 to 40 μm • Data format: binary or Gray code; incremental/ decremental • Power supply 10...32 Vdc • Resistance to vibration (DIN IEC68T2/6 15g) • IP67 protection • Work temperature: -30...+90°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimised mechanical structure • Strokes from 50 to 2500 mm • Fast installation by mean of steel brackets • Sliding or floating magnetic cursor • Synchronous Serial Interface direct to controllers • Output data resolution available from 20 to 40 μm • Data format: binary or Gray code; incremental/ decremental • Power supply 10...32 Vdc • Resistance to vibration (DIN IEC68T2/6 12g) • IP67 protection • Work temperature: -30...+90°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimised mechanical structure • Strokes from 50 to 4000mm • Sliding or floating magnetic cursor • Availability of several analogue outputs (voltage or current) for direct position and speed measurement or reverse measurement (only position) • Single or double cursors models availability • Power supply 24Vdc ±20% • Resistance to vibration (DIN IEC68T2/6 15g) • IP67 protection • Work temperature: -30...+85°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU