Loading...
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainless steel, 316 stainless steel, titanium. • Watt densities up to 35 watts per square inch (5.4 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene termimal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium. • Watt densities up to 18 watts per square inch (2.7 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene termimal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • Range of measurement: from 100 N to 2kN • Accuracy class: 0,5% • Corrosion resistant • Internally generated calibration signal • Orientation of the axis of maximum sensitivity for 35° independently from the position of the fixing holes • Grade of protection: IP65 (DIN 40050) • Integrated protection against overloads
  • Features • Ranges: from 0...4 bar to 0...1000 bar (0...60psi to 0...15000psi) • Accuracy: ± 0.1% FS typical • Complete range of voltage/current outputs • Stainless Steel construction • Protection rating: IP65/IP67 • Wetted parts17-4PH • Temperature range -40...+105°C
  • Features • Ranges: from 0...10 bar to 0...1000 bar (0...150psi to 0...15000psi) • Accuracy: ± 0.15% FSO typical • Protection rating: IP65/IP67 • Wetted parts 17-4PH • Temperature range -40...+120°C
  • Features • Ranges: from: 0...1000 to 0...5000 bar • Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...6Vdc / 1...10Vdc • Protection: IP65/IP67 • Wetted parts: 15-5PH / 17-4PH stainless steel • Measurement diaphragm with monolithic stainless steel structure • Digital Auto-Zero & Span function • Suitable for measuring static and dynamic pressure *
  • Features • Ranges: from: 0...1000 to 0...5000 bar • Accuracy: ± 0.1% FSO typical • Protection: IP65/IP67 • Internal calibration signal • Wetted parts: 15-5PH / 17-4PH stainless steel • Operating temperature: -30...+120°C • Measurement diaphragm with monolithic stainless steel structure • Suitable for measuring static and dynamic pressure *
  • Features • Ranges: from 0...25 to 0...600 bar • Output signal 4...20mA 2-wires / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...6Vdc / 1...10Vdc • Protection rating: IP65/IP67 • Wetted parts: 17-4PH Stainless Steel • Miniature flush fitting stainless steel measuring diaphragm • Magnetic or External Autozero function
  • Features • Ranges: from 0...10 to 0...1000 bar • Output signal 4...20mA 2-wires / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...6Vdc / 1...10Vdc • Protection rating: IP65/IP67 • Wetted parts: 17-4PH Stainless Steel • Flush fitting stainless steel measuring diaphragm • Digital Autozero & Span function
  • Features • Ranges: from: 0...10 to 0...1000 bar 0...150 to 0...15000 psi) • Accuracy: ±0.2% FSO typical • Protection rating: IP65/IP67 • Wetted parts: 17-4PH • Temperature range: -40...+120°C • Flush fitting stainless steel measuring diaphragm • Internal calibration signal
  • Features • Course Magnetic Autozero • Fine Magnetic Autozero • Calibration Signal 80% FS • Magnetic Autospan • Partial reset function • Total reset function
  • Features • Course Magnetic Autozero • Fine Magnetic Autozero • Calibration Signal 80% FS • Magnetic Autospan • Partial reset function • Total reset function
  • Features • Ranges: from 0...3 to 0...1000 bar and ranges from -1...+1 to -1...+10 bar • Output signal 4...20mA 2-wires / 0.1...5.1Vdc /0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...10Vdc • Protection rating: IP65/IP67 • Wetted parts AISI 430F and 17-4PH • Available with a variety of process connections, both standard and custom
  • Features • Ranges: from 0...3 to 0...1000 bar and ranges from -1...+1 to -1...+10 bar • Output signal 4...20mA 2-wires / 0.1...5.1Vdc /0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...10Vdc • Protection rating: IP65/IP67 • Wetted parts AISI 430F and 17-4PH • Available with a variety of process connections, both standard and custom
  • Features • Designed for Performance and Safety • Durable Constuction
  • Features • Dew point calibration, highly accuracy, 4 ... 20 mA and RS-485 output • Reduce insensitivity temperature zone, quickly response • Hysteresis compensation, resistance to moisture, extreme high and low humidity impact • EMC anti-interference, anti-condensation, low-temperature influence, long-term stability • Three thread (1/2″PT, 1/2″G, and 5/8″UNF) mode can be selected
  • Features
    • Industrial sensor comes with high accuracy and long-term stability
    • Capable of temperature compensation and linear adjustment
    • Multifunction physical quantities ─ temperature & humidity/dew point/ frost point/wet-bulb temp./vapor pressure/mixture ratio/absolute humidity/ specific enthalpy
    • Standard 2 analogue output or Modbus RS-485
    • Option analogue output+ RS-485
    • Probe : PC or S.S.;Remote type : PVC or TEFLON cable
    • Power supply : 8-35VDC and 12-35VAC
    • RS-485 and Modbus RTU
    • Free programmable software - physical quantities/output/data logger/charts/calibration
    • Option : USB to RS-485 Converter
     
  • Features • Industrial sensor comes with high accuracy and long-term stability • Capable of temperature compensation and linear calibration • 2 analog output or Modbus RS-485 • Optional analog output + RS-485 • Probe:PC • Power supply:DC 8 ... 35 V and AC 12 ... 30 VRS-485 and Modbus RTU • Free programmable software - Physical quantities / Output / Data logger / Charts / Calibration
  • Features • Excellent long-term stable ability • Cost-effective and accurate measurement • Outstanding long-term performance • Voltage or current outputs
  • Features • Excellent long-term stable ability • Cost-effective and accurate measurement • Outstanding long-term performance • Voltage or current outputs
  • Features • Measuring temperature and humidity • Analog outputs and RS-485 • Quick easy installation and maintenance due to well designed • Cost-efficient and reliable • Data can be logged and transferred to PC via RS-485 function link free software
  • Features • IP65 , rugged aluminum case, fit in variety harsh environment • Capable of temperature compensation. Linear adjustment temperature & humidity by computer, analog output or option RS-485 • Measure high accuracy Temp. & humidity, reaction quickly, the sensor can work well after temporary condensation, long term stable in high humidity environment • Process Temp. : up to 200°C, S.S. probe proof pressure : 10 bar, metal connector : installation repeatedly • Switch multifunction physical quantities:[%RH]、[°C]、[mbar]、[g/kg]、[g/m3]、[kj/kg] • Calibration physical quantities, measuring range, analog output, station, etc • Free calibration software : data logger / record 65535 datas / charts
  • Features
    •  IP65 , rugged aluminum case, fit in variety harsh environment
    • Capable of temperature compensation. Linear adjustment temperature & humidity by computer, analog output or option RS-485
    • Measure high accuracy Temp. & humidity, reaction quickly, the sensor can work well after temporary condensation, long term stable in high humidity environment
    • Process Temp. : up to 200°C, S.S. probe proof pressure : 10 bar, metal connector : installation repeatedly
    • Switch multifunction physical quantities:[%RH]、[°C]、[mbar]、[g/kg]、[g/m3]、[kj/kg]
    • Calibration physical quantities, measuring range, analog output, station, etc
    • Free calibration software : data logger / record 65535 datas / charts
  • Features • IP67, Stainless steel SUS304, Pressure resistance 16 bar • 330° rotatable, lightweight, unrestricted installation • Optional on-site real-time display • Process temperature up to 180°C, custom up to 200°C (Optional) • Output:Analog / RS-485 • Wide measurement range, Temp. : -40 ... +180°C, Humidity : 0 ... 100%RH • Measuring parameter:relative humidity, dew point temperature, frost point temperature, wet-bulb temperature, vapor pressure, mixture ratio, absolute humidity and specific enthalpy.
  • Features • Integrated 3 sensors in 1 device with LCD display • Measuring temperature, humidity and carbon dioxide • 2 analog outputs and Modbus RS-485 • Optional analog output + RS-485 • Quick easy installation and maintenance due to well designed • Cost-efficient and reliable • Data can be logged and transferred to PC via RS-485 function link free software
  • Features • Rectangular housing • Screw connection • 3 contacts: • Nickel-plated light alloy, silver-plated brass contact, thermocouple contacts, PBT insert
  • Features • More compact and lower price than tubular heat exchangers: • Improved reliability due to all welded construction: • Low internal volume • Compact modular design • Improved efficiency • Innovative design • Chemical compatibility
  • Features
    •  Capacitive humidity sensor & Pt100
    • 4 ... 20 mA / 0 ... 10 V / RS-485 Output
    • Accuracy:±0.2°C (Temperature),±2%RH (Humidity)
    • Small size and light weight, can be mounted fast and easily
    • Polycarbonate housing, great electrical insulation and flame-retardant properties
    • RS-485 programmable software : Data logger / Charts
  • Features • Range of measurement: from 10 to 100 kN • Accuracy class: 0,2% • All stainless steel construction • Corrosion resistant • Internally generated calibration signal • Grade of protection: IP65 (DIN 40050)
  • Features • Years of trouble-free performance in the most demanding chemical applications, such as semiconductor, FPD, MEMS, & biomedical industries • PTFE heater element with 38mm (.015 in.) thick fluoropolymer sheath for safety & long service life • Patented “purged” element design ensures maximum element life by removing chemical • permeation • 100% fluoropolymer wetted surfaces for virtually any non-flammable process solutions including HF & KOH • Low Watt density design promotes process temperature uniformity
  • Features • Universal mounting on Transducers with 4-20 mA Output; Plug DIN43650 • No additional Power Supply required • Easy to programming using Push Buttons • Compact Sandwich construction • Good Readability through LED-Display • Alarm: Open-Collector-Output
  • Features • Range of measurement: from100 to 20.000 Kg • Accuracy class: 0,2% • All stainless steel construction • Corrosion resistant • Internally generated calibration signal • Grade of protection: IP67 (DIN 40050)

Title

Go to Top