  • Features • For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection • Heavy wall metal sheaths and screwplug in 316 stainless steel and titanium • Watt densities up to 45-55 watts per square inch for 316 Stainless steel and <60 watts per square inch for titanium ensure long life service • Vapor tight, flame retardant PVC enclosure • Temperature and level controls sized to match the heater • Lower watt densities for highly viscous solutions
  • Features • For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection • Heavy wall metal sheaths available in: steel, 304 stainless steel, 316 stainless steel and titanium • Watt densities up to 40 watts per square inch (6.2 w/cm²) ensure long service life • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater • Lower watt densities for highly viscous solutions
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium. • Watt densities up to 46 watts per square inch (6.2 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainless steel, 316 stainless steel, titanium. • Watt densities up to 46 watts per square inch (7.1 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Optional patented purge feature promotes longer heater life • Lower Watt densities available for highly viscous solutions & technical acids
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Optional patented purge feature promotes a longer heater life by reducing chemical permeation • Lower Watt densities available for highly viscous solutions & technical acids
  • Features • For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection • Heavy wall metal sheaths and screwplug in 316 stainless steel and titanium • Watt densities up to 45-55 watts per square inch for 316 Stainless steel and <60 watts per square inch for titanium ensure long life service • Vapor tight, flame retardant PVC enclosure • Temperature and level controls sized to match the heater • Lower watt densities for highly viscous solutions
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Lower watt densities for highly viscous solutions & technical acids
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower watt densities for highly viscous solutions & technical acids
  • Features • Innovative Design for Ultra-High-Purity (UHP) • Modular & Configurable • Low Internal Volume • Safety & Reliability
  • Features • Vapor resistant, flame retardant polypropylene terminal. • Heavy wall metal sheaths available in 316 stainless steel, carbon steel, incoloy and titanium. 316 Stainless Steel standard with metal explosion resistant M2 terminal enclosure. • Vapor-resistant, painted metal enclosures. • Grounded construction and built-in P1 thermal protector for solutions up to 180°F (82°C). • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions and long service life (up to 40 watts per square inch - 6.2w/cm2). • 3” and 5” fluoropolymer flanged heaters.
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element and PVDF screw plug reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids
  • Features • Engineered for Safety • Indirect Heating Design • Advanced Cleanliness • Designed for Performance
  • Features • Wide variety of materials available for use in heating or cooling applications for alkaline or acid solutions and rinse tanks. Check solution guide or consult with • your chemical supplier for proper sheath material. • Heavy wall, 20 gauge metal tubing available in steel, 316 stainless steel and titanium. • 1” diameter tubing and 1” MNPT connection fittings standard. • 4.6 square foot to 89.9 square foot of exchange area • Single point connections reduce the potential for leaks and simplify installation
  • Features • Outstanding Cleanliness • Easy Maintenance with Minimal Downtime • Reliable • Low Cost of Ownership • Secondary Containment • Excellent Responsiveness • No O-Rings • No Dead Zones • Low Pressure Drop
  • Features • Wide variety of materials available for use in heating or cooling applications for alkaline or acid solutionsand rinse tanks. Check solution guide or consult with your chemical supplier for proper sheath material • Heavy wall, 18 gauge metal tubing available in steel, 316 stainless steel and titanium • 1” diameter tubing and 1” MNPT connection fittings standard • Single point connections reduce the potential for leaks and simplify installation • Tubing sizes: ⅜ inch diameter through 1¼ inch diameter • Helical sizes: From 3¼ inch to 10 ft. diameter available based on tube diameter and wall thickness • Wall thickness: .035 through .065 inches
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes longer heater life
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes longer heater life
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes longer heater life
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes longer heater life
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density Design of 10 W/in2 (1.5 W/cm2) • Flexible riser with 4 ft. (1.2m) of continuous PTFE cable leading to vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes a longer heater life by reducing chemical permeation
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Flexible riser with 4 ft. (1.2m) of continuous PTFE cable leading to vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes a longer heater life by reducing chemical permeation
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Flexible riser with 4 ft. (1.2m) of continuous PTFE cable leading to vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes a longer heater life by reducing chemical permeation
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element and PVDF screw plug reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium. • Watt densities up to 18 watts per square inch (2.8 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene termimal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • Complete (turn-key) System • DAC™ (Demand Anticipation Control) Temperature Control System • Patented Purged PTFE-Covered Heating Element Design
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium • Watt densities up to 35 watts per square inch (5.4 w/cm²) ensure long service life • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Temperature and level controls sized to match the heater • Lower watt densities for highly viscous solutions