- HRC-3000
- HRC-6000
-
Features
- Highly adaptable to most applications where electrical heating is required. They can be used in their straight form or bent into various shapes.
- Used in free air, clamped to a surface, placed inside a groove, or cast into metal.
- Use 80% Nickel 20 % Chromium high-grade coiled resistance wire as a heating core.
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes longer heater life
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes longer heater life
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes longer heater life
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density of 10 W/in2 (1.5 W/cm2) • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes longer heater life
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density Design of 10 W/in2 (1.5 W/cm2) • Flexible riser with 4 ft. (1.2m) of continuous PTFE cable leading to vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes a longer heater life by reducing chemical permeation
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Flexible riser with 4 ft. (1.2m) of continuous PTFE cable leading to vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes a longer heater life by reducing chemical permeation
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Flexible riser with 4 ft. (1.2m) of continuous PTFE cable leading to vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids • Optional patented purge feature promotes a longer heater life by reducing chemical permeation
-
Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element and PVDF screw plug reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids
-
Viscous materials such as syrup, sugar, and fats can be difficult to discharge from an IBC. Heating the container with an IBC heating jacket can make materials smoother and less viscous, reducing waste and expense.
- 1, 2, or 3 thermostats adjustable from 0-90°C
- Durable, lightweight design with quick release buckles
- Compatible with standard 1000L containers
- Can be used to heat a variety of industrial liquids
-
Principal Characteristics • Transducer with exposed tracks, allowing rod diameter is reduced to be reduced to a minimum to permit installation in small cylinders. • Thanks to a special constructive technique, the IC transducer provides high resistance to the working pressures of oil-pressure cylinders (max 340 bar) • Available with internal flanges or external threads to guarantee mechanical compatibility with all principal cylinder types.
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • “Mercury free” hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH • IO-Link output, ready for “Industry 4.0” • Rangeabilty: 3:1 • PLd and SIL2 approvals for Functional safety • Autozero function • Auxiliary information over IO-Link protocol
-
Features • Upto 16 inputs/16 outputs • For Temperature, Pressure, Flow, Level, RH, Conductivity, etc. • Various Input (X)/Output (Y) combinations : X4Y0, X4Y8, X8Y4, X8Y16, X16Y16, etc • Universal Input : 8 Thermocouples, Pt100, mV or mA input front panel selection without DIP for each channel • Front panel user calibration • Input burn protection • Non-volatile memory for parameters - no batteries • 3 key, 5 level programming • Setpoint and level locks • Tactile membrane keypad • 5 software versions : Indicator, Multisetpoint, Grouping, etc • RS485 with MODBUS RTU • Powerful, flexible SCADA software available • FDA21CFR Part11 compliant SCADA version also • Option : Printer interface (no computer needed) • 85~265 V AC SMPS or 24 V DC supply
-
Features • Up to 16 inputs/16 outputs • For Temperature, Pressure, Flow, Level, RH, Conductivity, etc. • Various Input (X)/Output (Y) combinations : X4Y0, X4Y8, X8Y4, X8Y16, X16Y16, etc • Universal Input : 8 Thermocouples, Pt100, mV or mA input front panel selection without DIP for each channel • Front panel user calibration • Input burn protection • Non-volatile memory for parameters - no batteries • 3 key, 5 level programming • Setpoint and level locks • Tactile membrane keypad • 5 software versions : Indicator, Multisetpoint, Grouping, etc • RS485 with MODBUS RTU • Powerful, flexible SCADA software available • FDA21CFR Part11 compliant SCADA version also • Option : Printer interface (no computer needed) • 85~265 V AC SMPS or 24 V DC supply