Features • ½-inch (13mm) PFA tubing, .030” (.76mm) thick • All welded construction (shell) • 4½-inch (114mm) diameter polypropylene or PVDF shell • Internally baffled for enhanced heat exchanger performance • “U” factor (depending on flow rate): 25-50 BTU/(hr. x ft² x °F) = 142-284 J/(s x m² x °C) • Shell-side drain connection
-
Main Characteristics • Optimized mechanical structure • Strokes from 50 to 2500 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Power supply 10....32 Vdc • Resistance to vibration (DIN IEC68T2/6 12g) • Protection IP67 • Work temperature: -30°…+90°C • Synchronous Serial Interface direct to controllers • Output data resolution available from 20 to 40μm • Data format: binary or Gray code; incremental/decremental • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Optimized mechanical structure • Strokes from 50 to 2500 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Work temperature: -30°…+75°C • Resistance to vibrations (DIN IEC68T2/6 12g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Magnetostrictive technology • Strokes from 50 to 1500 mm • Optimized mechanical structure • Rod, nipple, exagonal flange AISI 316 • Work temperature: -20....+75°C • Resistance to vibrations (DIN IEC68T2/6 12g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Optimized mechanical structure • Strokes from 50 to 4000 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Power supply 10....32 Vdc • Resistance to vibration (DIN IEC68T2/6 15g) • Protection IP67 • Work temperature: -30°…+90°C • Synchronous Serial Interface direct to controllers • Output data resolution available from 0.5 to 40μm • Data format: binary or Gray code; incremental/decremental • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Optimized mechanical structure • Strokes from 50 to 4000 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Work temperature: -30°…+85°C • Resistance to vibrations (DIN IEC68T2/6 15g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Optimised mechanical structure • Strokes from 50 to 2500 mm • Fast installation by mean of steel brackets • Sliding or floating magnetic cursor • Synchronous Serial Interface direct to controllers • Output data resolution available from 20 to 40 μm • Data format: binary or Gray code; incremental/ decremental • Power supply 10...32 Vdc • Resistance to vibration (DIN IEC68T2/6 12g) • IP67 protection • Work temperature: -30...+90°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Optimised mechanical structure • Strokes from 50 to 4000mm • Sliding or floating magnetic cursor • Availability of several analogue outputs (voltage or current) for direct position and speed measurement or reverse measurement (only position) • Single or double cursors models availability • Power supply 24Vdc ±20% • Resistance to vibration (DIN IEC68T2/6 15g) • IP67 protection • Work temperature: -30...+85°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Strokes from 50 to 1500mm • Sliding or floating magnetic cursor • Direct and reverse analog output for displacement • Standard valve or M12 connector • Work temperature: -20...+75°C • IP67 protection • Power supply 24Vdc ±20% • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Optimised mechanical structure • Strokes from 50 to 4000 mm • Fast installation by mean of steel brackets • Sliding or floating magnetic cursor • Synchronous Serial Interface direct to controllers • Output data resolution available from 0.5 to 40 μm • Data format: binary or Gray code; incremental/ decremental • Power supply 10...32 Vdc • Resistance to vibration (DIN IEC68T2/6 15g) • IP67 protection • Work temperature: -30...+90°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Main Characteristics • Optimised mechanical structure • Strokes from 50 to 4000mm • Sliding or floating magnetic cursor • Availability of several analogue outputs (voltage or current) for direct position and speed measurement or reverse measurement (only position) • Single or double cursors models availability • Power supply 24Vdc ±20% • Resistance to vibration (DIN IEC68T2/6 15g) • IP67 protection • Work temperature: -30...+85°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
-
Features The W92 is a melt pressure and temperature monitoring system which comes complete with the following items: • W32-6-M-xxxx-1-4-D-000 (oil-filled melt pressure transducer with type “J” thermocouple) • 40TB-10-RRR-2-0-1 (1/4 DIN pressure and temperature indicator) • C08WLS (25 foot 6-pin cable) • SF18 (mounting bracket)
-
Features • Ranges: from 0...0.05 bar to 0...60 bar (0...1 to 0...1000 psi) • Complete range of voltage/current outputs • Protection rating: IP65/IP67 • Wetted parts: AISI316L • Operating temperature range -40...+85°C • Accuracy: ± 0.15% FS typical • Fill Fluid: silicone oil • Available absolute ranges • Available “Barometric” range (0.8-1.2 bar abs) • Available low ranges (50mbar and 100mbar)
-
Features • Range of measurement: from 100 N to 2kN • Accuracy class: 0,5% • Corrosion resistant • Internally generated calibration signal • Orientation of the axis of maximum sensitivity for 35° independently from the position of the fixing holes • Grade of protection: IP65 (DIN 40050) • Integrated protection against overloads
-
Features • Ranges: from: 0...1000 to 0...5000 bar • Output signal 4...20mA 2 wires / 0,1...5,1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...6Vdc / 1...10Vdc • Protection: IP65/IP67 • Wetted parts: 15-5PH / 17-4PH stainless steel • Measurement diaphragm with monolithic stainless steel structure • Digital Auto-Zero & Span function • Suitable for measuring static and dynamic pressure *
-
Features • Ranges: from 0...25 to 0...600 bar • Output signal 4...20mA 2-wires / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...6Vdc / 1...10Vdc • Protection rating: IP65/IP67 • Wetted parts: 17-4PH Stainless Steel • Miniature flush fitting stainless steel measuring diaphragm • Magnetic or External Autozero function
-
Features • Ranges: from 0...10 to 0...1000 bar • Output signal 4...20mA 2-wires / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...6Vdc / 1...10Vdc • Protection rating: IP65/IP67 • Wetted parts: 17-4PH Stainless Steel • Flush fitting stainless steel measuring diaphragm • Digital Autozero & Span function
-
Features • Ranges: from 0...3 to 0...1000 bar and ranges from -1...+1 to -1...+10 bar • Output signal 4...20mA 2-wires / 0.1...5.1Vdc /0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...10Vdc • Protection rating: IP65/IP67 • Wetted parts AISI 430F and 17-4PH • Available with a variety of process connections, both standard and custom
-
Features • Ranges: from 0...3 to 0...1000 bar and ranges from -1...+1 to -1...+10 bar • Output signal 4...20mA 2-wires / 0.1...5.1Vdc /0.1...10.1Vdc / 0...5Vdc / 0...10Vdc / 1...5Vdc / 1...10Vdc • Protection rating: IP65/IP67 • Wetted parts AISI 430F and 17-4PH • Available with a variety of process connections, both standard and custom
-
Features • Dew point calibration, highly accuracy, 4 ... 20 mA and RS-485 output • Reduce insensitivity temperature zone, quickly response • Hysteresis compensation, resistance to moisture, extreme high and low humidity impact • EMC anti-interference, anti-condensation, low-temperature influence, long-term stability • Three thread (1/2″PT, 1/2″G, and 5/8″UNF) mode can be selected
-
Features
- Industrial sensor comes with high accuracy and long-term stability
- Capable of temperature compensation and linear adjustment
- Multifunction physical quantities ─ temperature & humidity/dew point/ frost point/wet-bulb temp./vapor pressure/mixture ratio/absolute humidity/ specific enthalpy
- Standard 2 analogue output or Modbus RS-485
- Option analogue output+ RS-485
- Probe : PC or S.S.;Remote type : PVC or TEFLON cable
- Power supply : 8-35VDC and 12-35VAC
- RS-485 and Modbus RTU
- Free programmable software - physical quantities/output/data logger/charts/calibration
- Option : USB to RS-485 Converter
-
Features • Industrial sensor comes with high accuracy and long-term stability • Capable of temperature compensation and linear calibration • 2 analog output or Modbus RS-485 • Optional analog output + RS-485 • Probe:PC • Power supply:DC 8 ... 35 V and AC 12 ... 30 VRS-485 and Modbus RTU • Free programmable software - Physical quantities / Output / Data logger / Charts / Calibration
-
Features • IP65 , rugged aluminum case, fit in variety harsh environment • Capable of temperature compensation. Linear adjustment temperature & humidity by computer, analog output or option RS-485 • Measure high accuracy Temp. & humidity, reaction quickly, the sensor can work well after temporary condensation, long term stable in high humidity environment • Process Temp. : up to 200°C, S.S. probe proof pressure : 10 bar, metal connector : installation repeatedly • Switch multifunction physical quantities:[%RH]、[°C]、[mbar]、[g/kg]、[g/m3]、[kj/kg] • Calibration physical quantities, measuring range, analog output, station, etc • Free calibration software : data logger / record 65535 datas / charts
-
Features
- IP65 , rugged aluminum case, fit in variety harsh environment
- Capable of temperature compensation. Linear adjustment temperature & humidity by computer, analog output or option RS-485
- Measure high accuracy Temp. & humidity, reaction quickly, the sensor can work well after temporary condensation, long term stable in high humidity environment
- Process Temp. : up to 200°C, S.S. probe proof pressure : 10 bar, metal connector : installation repeatedly
- Switch multifunction physical quantities:[%RH]、[°C]、[mbar]、[g/kg]、[g/m3]、[kj/kg]
- Calibration physical quantities, measuring range, analog output, station, etc
- Free calibration software : data logger / record 65535 datas / charts
-
Features • IP67, Stainless steel SUS304, Pressure resistance 16 bar • 330° rotatable, lightweight, unrestricted installation • Optional on-site real-time display • Process temperature up to 180°C, custom up to 200°C (Optional) • Output:Analog / RS-485 • Wide measurement range, Temp. : -40 ... +180°C, Humidity : 0 ... 100%RH • Measuring parameter:relative humidity, dew point temperature, frost point temperature, wet-bulb temperature, vapor pressure, mixture ratio, absolute humidity and specific enthalpy.
-
Features • Integrated 3 sensors in 1 device with LCD display • Measuring temperature, humidity and carbon dioxide • 2 analog outputs and Modbus RS-485 • Optional analog output + RS-485 • Quick easy installation and maintenance due to well designed • Cost-efficient and reliable • Data can be logged and transferred to PC via RS-485 function link free software
-
Features
- Capacitive humidity sensor & Pt100
- 4 ... 20 mA / 0 ... 10 V / RS-485 Output
- Accuracy:±0.2°C (Temperature),±2%RH (Humidity)
- Small size and light weight, can be mounted fast and easily
- Polycarbonate housing, great electrical insulation and flame-retardant properties
- RS-485 programmable software : Data logger / Charts
-
Features • Years of trouble-free performance in the most demanding chemical applications, such as semiconductor, FPD, MEMS, & biomedical industries • PTFE heater element with 38mm (.015 in.) thick fluoropolymer sheath for safety & long service life • Patented “purged” element design ensures maximum element life by removing chemical • permeation • 100% fluoropolymer wetted surfaces for virtually any non-flammable process solutions including HF & KOH • Low Watt density design promotes process temperature uniformity