  • Application
    • Flanged immersion heaters are one of the most widely used methods for heating gases and liquids (such as water, oil, heat transfer fluid and corrosive solutions ).
    • Designed for use in tanks and pressurized vessels, they are easy to install and maintain to provide heat for many processes.
    • The direct immersion method is energy efficient and easily monitored and controlled. "Hot Water Storage Tanks" "Warming Equipment" "Preheating all Grades of Oil" "Food Processing Equipment" "Cleaning and Rinsing Tanks" "Heat Transfer Systems" "Process Air Equipment" "Boiler Equipment" "Freeze Protection of Any Fluid"
    Application Factors
    • The heated media, viscosity, specific heat, density and corrosive properties.
    • Contaminants are present in the medium.
    • The heater sheath material corrosion resistant properties.
    • Watt density of the heating element the heat output per square inch.
    • Maximum sheath temperature this is the recommended maximum sheath temperature of the element material. It is not the operating temperature of the heated medium
  • Application
    • Screw Plug Immersion Heaters are used for heating liquids and gases in a variety of processes.
    • These heaters are ideal for process water heating and freeze protection.
    • These heaters are ideal for process water heating and freeze protection. All types of oils and heat transfer solutions can also be heated using these compact, easily controlled units.
    • The direct immersion method is energy efficient and well suited for many applications. "Hot Water Storage Tanks" "Warming Equipment" "Preheating all Grades of Oil" "Food Processing Equipment" "Cleaning and Rinsing Tanks" "Heat Transfer Systems" "Process Air Equipment" "Boiler Equipment" "Freeze Protection of Any Fluid"
    Application Factors
    •  The heated media, viscosity, specific heat, density and corrosive properties.
    • Contaminants or pH present in the media.
    • The corrosion resistant properties of heater sheath material.
    • Watt density of the heating element the heat output per square inch.
    • Screw plug material.
  • Features
    • Highly adaptable to most applications where electrical heating is required. They can be used in their straight form or bent into various shapes.
    • Used in free air, clamped to a surface, placed inside a groove, or cast into metal.
    • Use 80% Nickel 20 % Chromium high-grade coiled resistance wire as a heating core.
  • Features
    • Highly adaptable to most applications where electrical heating is required. They can be used in their straight form or bent into various shapes.
    • Used in free air, clamped to a surface, placed inside a groove, or cast into metal.
    • Use 80% Nickel 20 % Chromium high-grade coiled resistance wire as a heating core.
  • Application
    • Molds and dies
    • Food processing
    • Plastic molding
    • Packaging equipment
    • Hot stamping
    • Plastic extruders
    • Hot runner molds
    • Medical Equipment
    • Shoe Machinery
    • Semiconductor
    • Hot plates
    • Sealing
    • Fluid heating
  • Application
    • Molds and dies
    • Food processing
    • Plastic molding
    • Packaging equipment
    • Hot stamping
    • Plastic extruders
    • Hot runner molds
    • Medical Equipment
    • Shoe Machinery
    • Semiconductor
    • Hot plates
    • Sealing
    • Fluid heating
  • Features • Compact design • Double insulated • Integrated thermostat or hygrostat • Optional clip or screw fixing
  • Features • Compact heater • Integrated thermostat • Clip fixing • Optical Indicator • Temperature safety cut-out
  • Features • Compact design • DIN-Rail Mounting
  • Features • Ball bearing fan heater ensures long life • compact design • Aluminum case • IP20 Protection • internal connection piece
  • Features • Aluminum case • IP20 Protection
  • Features • High-flow Capacity • Ultra-High-Purity • Low-Mass Heat Exchanger • Compact Design
  • Features • ½-inch (13mm) PFA tubing, .030” (.76mm) thick • All welded construction (shell) • 4½-inch (114mm) diameter polypropylene or PVDF shell • Internally baffled for enhanced heat exchanger performance • “U” factor (depending on flow rate): 25-50 BTU/(hr. x ft² x °F) = 142-284 J/(s x m² x °C) • Shell-side drain connection
  • Features • More compact and lower price than tubular heat exchangers: • Improved reliability due to all welded construction: • Low internal volume • Compact modular design • Improved efficiency • Innovative design • Chemical compatibility
  • Features • Wide variety of materials available for use in heating or cooling applications for alkaline or acid solutionsand rinse tanks. Check solution guide or consult with your chemical supplier for proper sheath material • Heavy wall, 18 gauge metal tubing available in steel, 316 stainless steel and titanium • 1” diameter tubing and 1” MNPT connection fittings standard • Single point connections reduce the potential for leaks and simplify installation • Tubing sizes: ⅜ inch diameter through 1¼ inch diameter • Helical sizes: From 3¼ inch to 10 ft. diameter available based on tube diameter and wall thickness • Wall thickness: .035 through .065 inches
  • Features • Superior chemical resistance • Rugged construction • Long outstanding performance • Leak-free operation
  • Features • Superior chemical resistance • Rugged construction • Outstanding performance • Leak-free operation
  • Features • Wide variety of materials available for use in heating or cooling applications for alkaline or acid solutions and rinse tanks. Check solution guide or consult with • your chemical supplier for proper sheath material. • Heavy wall, 20 gauge metal tubing available in steel, 316 stainless steel and titanium. • 1” diameter tubing and 1” MNPT connection fittings standard. • 4.6 square foot to 89.9 square foot of exchange area • Single point connections reduce the potential for leaks and simplify installation
  • Features • Superior chemical resistance • Rugged construction • Outstanding performance • Corrosion resistant head
  • Features • Vapor resistant, flame retardant polypropylene terminal. • Heavy wall metal sheaths available in 316 stainless steel, carbon steel, incoloy and titanium. 316 Stainless Steel standard with metal explosion resistant M2 terminal enclosure. • Vapor-resistant, painted metal enclosures. • Grounded construction and built-in P1 thermal protector for solutions up to 180°F (82°C). • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions and long service life (up to 40 watts per square inch - 6.2w/cm2). • 3” and 5” fluoropolymer flanged heaters.
  • Features • For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection • Heavy wall metal sheaths and screwplug in 316 stainless steel and titanium • Watt densities up to 45-55 watts per square inch for 316 Stainless steel and <60 watts per square inch for titanium ensure long life service • Vapor tight, flame retardant PVC enclosure • Temperature and level controls sized to match the heater • Lower watt densities for highly viscous solutions
  • Features • For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection • Heavy wall metal sheaths and screwplug in 316 stainless steel and titanium • Watt densities up to 45-55 watts per square inch for 316 Stainless steel and <60 watts per square inch for titanium ensure long life service • Vapor tight, flame retardant PVC enclosure • Temperature and level controls sized to match the heater • Lower watt densities for highly viscous solutions
  • Features • Superior chemical resistance • Rugged construction • Outstanding performance • Corrosion resistant head
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainless steel, 316 stainless steel, titanium. • Watt densities up to 46 watts per square inch (7.1 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium. • Watt densities up to 46 watts per square inch (6.2 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • For use in most aqueous alkaline solutions and rinse tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection • Heavy wall metal sheaths available in: steel, 304 stainless steel, 316 stainless steel and titanium • Watt densities up to 40 watts per square inch (6.2 w/cm²) ensure long service life • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater • Lower watt densities for highly viscous solutions
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium. • Watt densities up to 18 watts per square inch (2.7 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene termimal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium. • Watt densities up to 18 watts per square inch (2.8 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene termimal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainless steel, 316 stainless steel, titanium. • Watt densities up to 35 watts per square inch (5.4 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene termimal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium • Watt densities up to 35 watts per square inch (5.4 w/cm²) ensure long service life • Vapor-resistant, flame retardant polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Temperature and level controls sized to match the heater • Lower watt densities for highly viscous solutions
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element and PVDF screw plug reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids
  • Features • Inert to most aqueous acid, alkaline, anodizing, & pickling solutions up to 100°C (212°F) • Rugged, heavy wall PTFE covered stainless steel element and PVDF screw plug reduces permeation. Guaranteed 100% pinhole free • Space saving & long service life with low Watt density design of 10 W/in2 (1.5 W/cm2) • Polypropylene terminal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit • Lower Watt densities available for highly viscous solutions & technical acids