GEFRAN

Home/GEFRAN
  • Features
    • Zero-crossing voltage switching (ZC)
    • Overtemperature protection
    • Compact designs
  • Features
    • Zero-crossing voltage switching (ZC)
    • Overtemperature protection
    • Compact designs
  • Features
    • Compact size from 10A to 120A
    • Load voltage 480V, 600Vac
    • IO-Link and Modbus RTU digital communication
  • Features
    • Compact size from 10A to 120A
    • Load voltage 480V, 600Vac
    • IO-Link and Modbus RTU digital communication
  • Features
    • Single/Three phase motor control up to 500Vac - 7A - 3 kW
    • Reverse rotation function
    • Emergency stop compliant to PL e / SIL 3
  • Features
    • Operator interface with large LCD Display,customizable, with choice of colors
    • Scrolling diagnostics messages, configurable, in the selected language
    • Easy, guided configuration, copy/paste parameters even with power off
    • Preventive maintenance with energy counters (kWh) and load switching
    • 16 function block applications
    • Timer, setpoint and algorithm programmer for controlling motorized valves
    • Advanced tuning of control parameters
    • Different password levels
    • Universal input configurable for thermocouples, resistance thermometers, linear inputs
    • Remote setpoint input
    • Relay, logic, isolated analog outputs
    • CT inputs for interrupted load diagnostics
    • RS485 serial communication in Modbus RTU
    • Removable faceplate for immediate replacement
    • Sampling time 60ms
    • 10V power supply for potentiometer and 24V for transmitter
  • Features
    • Current range from 15A up to 120A
    • Ultra slim dimension
    • IO-Link communication
  • Features • Command input from analogue voltage or current signal or potentiometer. • Switching at voltage zero crossing. • Partialization of wave train power with dynamically optimized time cycle. • Antiparallel double SCR • 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm • 4000V isolation between input circuit and power output • MOV (varistor) • Optional monitoring of interrupted load
  • Features • Command input from analogue voltage or current signal or potentiometer. • Switching at voltage zero crossing. • Partialization of wave train power with dynamically optimized time cycle. • Antiparallel double SCR • 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm • 4000V isolation between input circuit and power output • MOV (varistor) • Optional monitoring of interrupted load
  • Features
    • New application specific interfaces
    • Sensor battery level and status monitoring
    • Remote sensor identification
  • Features
    • Compact size from 10A to 120A
    • Load voltage 480V, 600Vac
    • IO-Link and Modbus RTU digital communication
  • Features • Universal input configurable from the faceplate • Acquisition of the input signal every 120msec ; resolution 30000steps • Two control outputs: relay, logic or analogue with Open/Close valve function • 3 configurable alarms • 2 analogue outputs (retransmission) • 2 digital inputs with configurable function • Auxiliary input for valve position potentiometer feedback • Heater Break or shortcircuit probe alarm • Self and Auto-tuning, Soft-start, Local/Remote setpoint, Auto/Man • Multiset function, timer set ramp  
  • Features • Operator interface with color touch screen display, 3.5 “ • Up to 8 PID control loops • Cascade, ratio and valve PID controls • Profile programmer with ramps and retention; synchronous and asynchronous • Up to 200 Programs with 50 segments • 3 password protected user levels • Energy meter (kWh) • Configurable logic operations • Configurable math functions • Data Log with Real Time Clock • Batch Report management • Open format files (CSV) or encrypted for DataLog and production batches • Setting up custom pages • Management of active and historic alarms • Active and historical alarm management • USB for data export and parameter cloning • Control parameter advanced tuning • Configurable analogue and digital I/O signals • HMI/SCADA/PLC data exchange via Ethernet Modbus TCP • Message language selection
  • Features • Operator interface with color touch screen display, 7” • Up to 16 PID control loops • Cascade, ratio and valve PID controls • Profile programmer with ramps and retention; synchronous and asynchronous • Up to 250 Programs with 50 segments • 3 password protected user levels • Energy meter (kWh) • Configurable logic operations • Configurable math functions • Data Log with Real Time Clock • Batch Report management • Open format files (CSV) or encrypted for DataLog and production batches • Setting up custom pages • Active and historical alarm management • USB for data export and parameter cloning • Control parameter advanced tuning • Configurable analogue and digital I/O signals • HMI/SCADA/PLC data exchange via Ethernet Modbus TCP • Message language selection
  • Features • Operator interface with large LCD Display, customizable, with choice of colors • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/ paste parameters even with power off • Preventive maintenance with energy counters (kWh) and load switching • 16 function block applications • Timer, setpoint and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • Universal input configurable for thermocouples, resistance thermometers, linear inputs • Remote setpoint input • Relay, logic, isolated analog outputs • Up to two CT inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU • Removable faceplate for immediate replacement • Sampling time 60 ms
  • Features • Operator interface with large LCD Display and three configurable bargraphs • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even with power off • Preventive maintenance with energy counters (kWh) and load switching • 32 function block applications • 8 Math application blocks • Timer, setpoint and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • 2 setpoint programmers (192 steps in 16 programs, or 12 programs with 16 fixed steps each) • 1 ingresso analogico lineare configurabile per funzioni ausiliarie • 2 PID control loops • 2 Programmatori di setpoint (192 passi in 16 programmi oppure 12 programmi da 16 passi fissi ciascuno) • Relay, logic, isolated analog outputs • Up to two TA inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU slave • RS485 serial communication in Modbus RTU master for reading/ writing information to Modbus slave devices • Ethernet Modbus TCP communication in Slave mode • Web server for browser access to web pages residing in the devvice, for monitoring and setting parameters • Bridge function for creation of Modbus RTU 485 sub-network • Weekly clock\calendar with RTC • Removable faceplate for immediate replacement • Accuracy 0,1%, sampling time 60 ms
  • Features • Operator interface with large LCD Display, customizable, with choice of colors • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even with power off • Preventive maintenance with energy counters (kWh) and load switching • 16 function block applications • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • Universal input configurable for thermocouples, resistance thermometers, linear inputs • Remote set point input • Relay, logic, isolated analog outputs • Up to two CT inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU • Removable faceplate for immediate replacement • Sampling time 60ms
  • Features
    • Operator interface with large LCD Display, customizable, with choice of colors
    • Scrolling diagnostics messages, configurable, in the selected language
    • Easy, guided configuration, copy/paste parameters even with power off
    • Preventive maintenance with energy counters (kWh) and load switching
    • 16 function block applications
    • Timer, setpoint and algorithm programmer for controlling motorized valves
    • Advanced tuning of control parameters
    • Different password levels
    • Universal input configurable for thermocouples, resistance thermometers, linear inputs
    • Remote setpoint input
    • Relay, logic, isolated analog outputs
    • Up to two CT inputs for interrupted load diagnostics
    • RS485 serial communication in Modbus RTU
    • Removable faceplate for immediate replacement
    • Sampling time 60ms
  • Features • Operator interface with large LCD Display and three configurable bargraphs • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even withe power off • Preventive maintenance with energy counters (kWh) and load switching • 32 function block applications • 8 Math application blocks • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • 2 Universal inputs configurable for thermocouples, resistance thermometers, linear inputs • 1 linear analog input configurable for auxiliary functions • 2 PID control loops • 2 set point programmers (192 steps in 16 programs, or 12 programs with 16 fixed steps each) • Relay, logic, isolated analog outputs • Up to two TA inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU slave • RS485 serial communication in Modbus RTU master for reading/ writing information to Modbus slave devices • Ethernet Modbus TCP communication in Slave mode • Web server for browser access to web pages residing in the device, for monitoring and setting parameters • Bridge function for creation of Modbus RTU 485 sub-network • Weekly clock\calendar with RTC • Removable faceplate for immediate replacement • Accuracy 0,1%, sampling time 60 ms
  • Features • Operator interface with large LCD Display, customizable, with choice of colors • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even with power off • Preventive maintenance with energy counters (kWh) and load switching • 16 function block applications • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • Universal input configurable for thermocouples, resistance thermometers, linear inputs • Remote set point input • Relay, logic, isolated analog outputs • Up to two CT inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU • Removable faceplate for immediate replacement • Sampling time 60ms
  • Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac or continuous • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Up to 2 isolated digital inputs with configurable function • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line. Protocol: GEFRAN MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
  • Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac , continuous, digital insulated • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line.Protocol: GEFRAN CENCAL or MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
  • Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac , continuous, digital insulated • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line. Protocol: GEFRAN CENCAL or MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
  • Features • Operator interface with color touch screen display, 7” • Up to 16 PID control loops • Cascade, ratio and valve PID controls • Profile programmer with ramps and retention; synchronous and asynchronous • Up to 250 Programs with 50 segments • 3 password protected user levels • Energy meter (kWh) • Configurable logic operations • Configurable math functions • Data Log with Real Time Clock • Batch Report management • Open format files (CSV) or encrypted for DataLog and production batches • Setting up custom pages • Active and historical alarm management • USB for data export and parameter cloning • Control parameter advanced tuning • Configurable analogue and digital I/O signals • HMI/SCADA/PLC data exchange via Ethernet Modbus TCP • Message language selection
  • Features • Operator interface with color touch screen display, 3.5 “ • Up to 8 PID control loops • Cascade, ratio and valve PID controls • Profile programmer with ramps and retention; synchronous and asynchronous • Up to 200 Programs with 50 segments • 3 password protected user levels • Energy meter (kWh) • Configurable logic operations • Configurable math functions • Data Log with Real Time Clock • Batch Report management • Open format files (CSV) or encrypted for DataLog and production batches • Setting up custom pages • Management of active and historic alarms • Active and historical alarm management • USB for data export and parameter cloning • Control parameter advanced tuning • Configurable analogue and digital I/O signals • HMI/SCADA/PLC data exchange via Ethernet Modbus TCP • Message language selection
  • Features • High impedance input >100 Mohm • Voltage output 0...10V • Linearity error < 0,02% full scale output • Can be connected simultaneously to two transducers • Low thermal drift 0,01% full scale / °C • Suitable for DIN rail mounting EN50035 and EN50022
  • Features • Interface module integrated in the connector • Standard output 0...10Vdc (PCIR 101) • Standard output 4...20mA(PCIR 102) • High linearity • Adjustable Zero and Span • Low zero and span thermal drift • 4 pole female DIN43650 connector for LTM and PKM potentiometer • DIN 43650 4-pin female connector for direct connection to LTM and PKM potentiometers (the DIN 43650 connector in the PCM series is smaller and cannot be connected directly)
  • Features • Sealed industrial version • Independent linearity up to ± 0,05% (standard ± 0,5%) • Working temperature: -55...+100°C • Repetibility 0,01% della C.E.T. • Life duration: >100x106 operations at 10 r.p.s. (within C.E.U.) • Infinite resolution • Electrical connection: 5-pole connector DIN 43322 • Grade of protection IP65 • Suitable for use in explosive environments with presence of gas (groups IIA, IIB, IIC) and combustible powders. Standards for simple device: ATEX CEI EN 50020 2003 - paragraph 5.4 a
  • Features • Models 09, 11, 20 • Servo mounting • Independent linearity up to ± 0,05% (standard ± 0,5%) • Repetibility 0,01% C.E.T. • Rotation speed ≤ 600 r.p.m. (within C.E.U.) • Life duration: >100x106 operations at 10 r.p.s. • Infinite resolution • Electrical terminals: turrets • Grade of protection IP40 • Suitable for use in explosive environments with presence of gas (groups IIA, IIB, IIC) and combustible powders. Standards for simple device: ATEX CEI EN 50020 2003 - paragraph 5.4 a
  • Principal Characteristics • Transducer with exposed tracks, allowing rod diameter is reduced to be reduced to a minimum to permit installation in small cylinders. • Thanks to a special constructive technique, the IC transducer provides high resistance to the working pressures of oil-pressure cylinders (max 340 bar) • Available with internal flanges or external threads to guarantee mechanical compatibility with all principal cylinder types.
  • Applicative Characteristics • The PMI-SLE transducer, is the amplified version of the PMI-SL, a product designed for all inside cylinder applications which require a smaller transducer (the rod diameter is only 12,7 mm). • The PMI Slim offers the same robustness: stainlessteel body, IP67 protection level, and pressure resistance up to 250 bar (400 bar peak) • Available with flanged or threaded heads, to guarantee mechanical compatibility with all main cylinder types • Patented solution • Ideal for applications inside hydraulic cylinders, demanding simple solutions which guarantee measurement repeatability.
  • Applicative Characteristics • The PMI-SL transducer, an evolution of the PMI-12, is designed for all inside cylinder applications which require a smaller transducer. For this reason, the diameter has been reduced to 12.7 mm. • The PMI Slim offers the same robustness as the PMI-12: AISI 316 stainless steel body, IP67 protection level, and pressure resistance up to 250 bar (400 bar peak) • Available with flanged or threaded heads, to guarantee mechanical compatibility with all main cylinder types • Patented solution • Ideal for applications inside hydraulic cylinders, demanding simple solutions which guarantee measurement repeatability
  • Main Characteristics • The PMI-12 transducer is designed for use inside oil pressure cylinders, applications that demand high strength. • The AISI316 stainless steel body and elevated protection level permit installation in cylinders with pressures up to 250 bar (400 bar peak). • Available with internal flanges or external threads to guarantee mechanical compatibility with all principal cylinder types. • Patented
  • Principal Characteristics • The PMA-12 transducer, a development of the PME series, is designed for installation with self-aligning joints. • The IP67 protection level makes the PMA-12 highly suitable for humid and wet environments and in temporary immersion (CEI EN 60529). • Available only with cable output. • Ideal for applications on metalworking and ceramics machines, as well as on earth-moving machines and utility vehicles. Recommended in all cases where the angle of the drive axle changes constantly.
  • Features • Rectilinear displacement transducer without drag shaft, completely water-tight (IP67), designed to work in humid environments (CEI EN 60529) • The PME series has an external magnetic actuator linked to an internal measurement cursor • The magnetic cursor replaces the drag shaft used in traditional displacement transducers, making the instrument even more compact • Installation is made simpler because there is no variation in the electrical output signal outside the Theoretical Electrical Stroke • The instrument can be used in compressed air applications with max. working pressure of 20 bar.
  • Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • Its high protection level and very small size make the PZ67-A unique in terms of reliability and flexible installation • It is ideal for glass cutting and washing machines or for honers and sanders if there is direct exposure to liquids or even just steam • Indicated for test and bench equipment, especially if outdoors

Title

Go to Top