Loading...
  • Features • Complete system for the strain-measurement on one tie bar • Direct display of the measured values in µe, kN or t • Quick and easy non-destructive assembly • High accuracy and linearity in tension and pressure (like bonded strain gauges) • Ideal for use on presses, injection-moulding and die-casting machines • One system for many different tie bar diameters (25…400mm) • Dynamic applications • 1- channel digital monitor DU1D • Ideal for self-construction load cells • Very compact and easy to use system
  • Features • Complete system for the simultaneous strain-measurement on up to four tie bars • Direct display of the measured values in µe, kN or t • Quick and easy non-destructive assembly • High accuracy and linearity in tension and pressure (like bonded strain gauges) • Ideal for use on presses, injection-moulding and die-casting machines • One system for many different tie bar diameters (25…400mm) • Dynamic applications • 4- channel digital monitor DU4D • USB connection for tie bar adjustment software (optional) • Analog output 0...10VDC (optional) • Very compact and easy to use system
  • Features • Available for all Sensormate sensors (2/4 bridges) • Direct display of the measured values in µe, kN or t • High accuracy and stable reset • Automatic reset, external reset and alarm output • Ideal for control cabinet installation (96x96mm, DIN 43700) • Battery operation possible (optional) / not rechargeable
  • Features • Available for all Sensormate sensors (2/4 bridges) • Direct display of the measured values in µe, kN or t • High accuracy and stable reset • Very bright displays and robust aluminum housing (IP52); Ideal for rough environments • USB connection for tie bar adjustment software (optional) • Analog output 0...10VDC (optional)
  • Features • Available for all Sensormate sensors (2/4 bridges) • Direct display of the measured values in µe, kN or t (via our Inspectmate software) • High accuracy and stable reset • Robust aluminium housing (IP50) • USB connection for tie bar adjustment software and power supply
  • Features • Amplifier with fast digital output • For dynamic and static applications • Very high strain gauge bridge offset range • Compact solid aluminium housing (IP65)
  • Features • Range of measurement: from 50 to 1.000 kg • Accuracy class: 0,2% • All stainless steel construction • Corrosion resistant • Grade of protection: IP67 (DIN 40050) • Compact size
  • Features • Range of measurement: from 100 to 50.000 Kg • Accuracy class: 0,2% • All stainless steel construction • Corrosion resistant • Internally generated calibration signal • Grade of protection: IP67 (DIN 40050)
  • Features • Range of measurement: from 5 to 20 kN • Accuracy class: 1% • All stainless steel construction • Corrosion resistant • Grade of protection: IP65 (DIN 40050) • Small size
  • Features • Range of measurement: from 750 to 1.500 kN • Accuracy class: 1% • Internally generated calibration signal • All stainless steel construction • Corrosion resistant • Grade of protection: IP65 ( norme DIN 40050)
  • Features • Range of measurement: from 100 to 3000 kN • Accuracy class: 0,5% • Elastic element in stainless steel • Corrosion resistant • Internally generated calibration signal • Grade of protection: IP65 (DIN 40050)
  • Features • Range of measurement: from 50 to 1000 kg • Accuracy class: 0,2% • All stainless steel construction • Corrosion resistant • Grade of protection: IP67 ( norme DIN 40050) • Compact size
  • Features • Range of measurement: from100 to 20.000 Kg • Accuracy class: 0,2% • All stainless steel construction • Corrosion resistant • Internally generated calibration signal • Grade of protection: IP67 (DIN 40050)
  • Features • Range of measurement: from 10 to 100 kN • Accuracy class: 0,2% • All stainless steel construction • Corrosion resistant • Internally generated calibration signal • Grade of protection: IP65 (DIN 40050)
  • Features • FLAT-body design • Good linearity • Designed integrate into machine • With EEPROM for sensitivity detection (option)
  • Features • FLAT-body design • Good linearity • Designed integrate into machine
  • Features • Range of measurement: from 20 to 200 Kg • Accuracy class: C (OIML R60) • All stainless steel construction • Corrosion resistant • Grade of protection: IP68 ( EN 60529)
  • Features • Range of measurement: from 100 N to 2kN • Accuracy class: 0,5% • Corrosion resistant • Internally generated calibration signal • Orientation of the axis of maximum sensitivity for 35° independently from the position of the fixing holes • Grade of protection: IP65 (DIN 40050) • Integrated protection against overloads
  • Features • Range of measurement: from 500 to 5.000 Kg • Accuracy class: D (OIML R60) • All stainless steel construction • Corrosion resistant • Insensitive to lateral loads • Low profile • Class of protection: IP66 (DIN 40050)
  • Features • Range of measurement: from 500 to 10.000 Kg • Accuracy class: D1 (OIML R60) • All stainless steel construction • Corrosion resistant • Insensitive to lateral loads • Grade of protection: IP66 ( DIN 40050)
  • Features • Linearity error <0,05%FSO • Voltage or current output • Low thermal drift <0,01%FSO/°C • Compact size
  • Main Characteristics • Strokes from 50 to 1500mm • Sliding or floating magnetic cursor • Direct and reverse analog output for displacement • Standard valve or M12 connector • Work temperature: -20...+75°C • IP67 protection • Power supply 24Vdc ±20% • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimised mechanical structure • Strokes from 50 to 4000mm • Sliding or floating magnetic cursor • Availability of several analogue outputs (voltage or current) for direct position and speed measurement or reverse measurement (only position) • Single or double cursors models availability • Power supply 24Vdc ±20% • Resistance to vibration (DIN IEC68T2/6 15g) • IP67 protection • Work temperature: -30...+85°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimised mechanical structure • Strokes from 50 to 4000mm • Sliding or floating magnetic cursor • Availability of several analogue outputs (voltage or current) for direct position and speed measurement or reverse measurement (only position) • Single or double cursors models availability • Power supply 24Vdc ±20% • Resistance to vibration (DIN IEC68T2/6 15g) • IP67 protection • Work temperature: -30...+85°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimised mechanical structure • Strokes from 50 to 2500 mm • Fast installation by mean of steel brackets • Sliding or floating magnetic cursor • Synchronous Serial Interface direct to controllers • Output data resolution available from 20 to 40 μm • Data format: binary or Gray code; incremental/ decremental • Power supply 10...32 Vdc • Resistance to vibration (DIN IEC68T2/6 12g) • IP67 protection • Work temperature: -30...+90°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimised mechanical structure • Strokes from 50 to 4000 mm • Fast installation by mean of steel brackets • Sliding or floating magnetic cursor • Synchronous Serial Interface direct to controllers • Output data resolution available from 0.5 to 40 μm • Data format: binary or Gray code; incremental/ decremental • Power supply 10...32 Vdc • Resistance to vibration (DIN IEC68T2/6 15g) • IP67 protection • Work temperature: -30...+90°C • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Features • ONDA technology • Stroke: 50 to 4000mm • Position resolution settable via software up to 1 μm • Speed resolution up to 0.25 mm/sec • Conforms to CE directives (EN 50081-1 50082-1) • Vibration-resistant (DIN IEC68T2/6 12 g) • IP67 protection rating • Controls up to four cursors simultaneously • Two M12 connectors for simplified connection to Profibus and one M8 connector for separate connection to power supply (transducer can be powered without having to be connected to bus) • Local intelligence • Profibus DPV0 interface on RS485 in conformity to IEC 61158
  • Main Characteristics • Magnetostrictive technology • Strokes from 50 to 1500 mm • Optimized mechanical structure • Rod, nipple, exagonal flange AISI 316 • Work temperature: -20....+75°C • Resistance to vibrations (DIN IEC68T2/6 12g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimized mechanical structure • Strokes from 50 to 2500 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Work temperature: -30°…+75°C • Resistance to vibrations (DIN IEC68T2/6 12g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimized mechanical structure • Strokes from 50 to 4000 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Work temperature: -30°…+85°C • Resistance to vibrations (DIN IEC68T2/6 15g) • Power supply 24Vdc ± 20% • Protection IP67 • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimized mechanical structure • Strokes from 50 to 2500 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Power supply 10....32 Vdc • Resistance to vibration (DIN IEC68T2/6 12g) • Protection IP67 • Work temperature: -30°…+90°C • Synchronous Serial Interface direct to controllers • Output data resolution available from 20 to 40μm • Data format: binary or Gray code; incremental/decremental • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Main Characteristics • Optimized mechanical structure • Strokes from 50 to 4000 mm • Wide range of connectors for the electrical connection • Rod, nipple, exagonal flange AISI 316 • Power supply 10....32 Vdc • Resistance to vibration (DIN IEC68T2/6 15g) • Protection IP67 • Work temperature: -30°…+90°C • Synchronous Serial Interface direct to controllers • Output data resolution available from 0.5 to 40μm • Data format: binary or Gray code; incremental/decremental • Electromagnetic compatibility EMC 2014/30/EU • Compliant to the directive RoHS 2011/65/EU
  • Features • ONDA technology • Stroke: 50 to 4000mm • Position resolution settable via software up to 1 μm • Speed resolution up to 0.25 mm/sec • Conforms to CE directives (EN 50081-1 50082-1) • Vibration-resistant (DIN IEC68T2/6 12 g) • IP67 protection rating • Controls up to four cursors simultaneously • Two M12 connectors for simplified connection to Profibus and one M8 connector for separate connection to power supply (transducer can be powered without having to be connected to bus) • Local intelligence • Profibus DPV0 interface on RS485 in conformity to IEC 61158
  • Main Characteristics • Absolute transducer • Strokes from 50 to 4000mm (RK-2-_ _ _ _ -N/E/S) • Digital output RS422 Start/Stop (RK-2-_ _ _ _ -S) • Direct analog output (RK-2-_ _ _ _ -N/K/E) • Operating temperature: -30...+90°C • Resistance to vibration (DIN IEC68T2/6 20g) • Power supply 18Vdc...30Vdc • Optional 12Vdc power supply (RK-2-_ _ _ _ -K) • The digital version (RK-2-_ _ _ _ -S) allows the remote connection (max. 50 m) of optional electronics for use of advanced analog (EKA)
  • Main Characteristics • Absolute transducer • Strokes from 50 to 4000mm (RK-4-_ _ _ _ -N/E/R) • Direct analog output (RK-4-_ _ _ _ -N/K/E) • Reverse analog output (RK-4-_ _ _ _ -R) • Operating temperature: -30...+90°C • Resistance to vibration (DIN IEC68T2/6 20g) • Power supply 18Vdc...30Vdc • Optional 12Vdc power supply (RK-4-_ _ _ _ -K)
  • Features • Absolute transducer • Stroke: 50 to 2500mm • Direct analog output (RK-5 N/K/E) • Inverse analog output (RK-5 O/I/R) • Operating temperature: -40...+105°C • Vibration-resistant (DIN IEC68T2/6 25g) • Power range 10VDC...32VDC current output • Power range 8VDC...32VDC voltage output
  • Features • The transducer has been improved in order to guarantee greater reliability under all conditions • A sturdier structure makes the LT series even stronger for applications with heavy vibration • Installation is made simpler by the absence of electrical signal variation in output, outside the Theoretical Electrical Stroke • The new grooves provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses, vertical presses, and on many other processing machines
  • Features • Measurement range: ±180° different values on request programmable in steps of ±15° (ONLY for analogue versions) • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +9…+36Vdc (see output signal for right supply voltage) • Output signal : 0.5...4.5V Ratiometric (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen, SAE J1939 • Electrical connections: AMP Superseal 6P 282108-1; DEUTSCH 6P DT04-6P • Resolution and speed of rotation: 12 bit (analog output); 14 bit (CANopen/SAE J1939 output); 120 rpm max. • Linearity: < ± 0.5% FS • Working and coefficient temperature: -40°C ... +85°C (higher values on request); thermal drift < 50 ppm/°C
  • Features • Measurement range: ±180° - different values on request programmable in steps of ±15° (ONLY for analogue versions) • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +9…+36Vdc (see output signal for right supply voltage) • Output signal: 0.5...4.5V RATIOMETRIC (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen, SAE J1939 • Electrical connections: AMP Superseal 6P 282108-1; cable output 18 AWG 1.65mm OD • Resolution and speed of rotation: 12 bit (analog output); 14 bit (CANopen/SAE J1939 output); 120 rpm max. • Linearity: < ±0.5%FS • Working and coefficient temperature: -40°C ... +85°C (higher values on request); thermal drift < 50 ppm/°C
  • Features
    • Measurement range : ±10° ±15° ±20° ±30° ±45° ±60° ±85° (dual axis XY); 360° (±180°) (single axis Z)
    • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +10…+36Vdc (see output signal for right supply voltage)
    • Output signal: 0.5...4.5V RATIOMETRIC (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen
    • Electrical connections: AMP Superseal 6P 282108-1; 6 wires output 18 AWG 1.65mm OD (cable+connector on request)
    • Resolution: 0.05° (±10° to ±20°); 0.05°(±30°); 0.1°(±45°); 0.1°(±60°); 0.1°(±85°); 0.1° (±180°) analog output; 0.05° CANopen output
  • Features • Ranges +/- 10,15,30,45,60,85 and 180 degrees • Accuracy from 0.15% to 0.5% in different models • Output 0-10V, 0.5-4.5V ratiometric, 4-20mA or CANopen • Environmental rating IP67 or better for cable entry • Compact size and rated to 85C
  • Features • Ranges 1800mm, 2300mm, 3300mm ……… 8300mm • Linearity 0.5% and repeatability 0.1% • Working temperature -40 to 85C • Life cycles 250000 (potientiometer) • Power 10-30VDC
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy <±0.25% FSO (H); <±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS • Quantity of NaK contained per model: K30 series (30mm³) [0.00183 in³], K31-K32-K33 series (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: KN0 series (30mm3) [0.00183 in3], KN1, KN2, KN3 (40mm3) [0.00244 in3] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features Electrical • Digital output signal with DP404 CAN OPEN communication protocol • Transmission frequency (Baud rate): 10 Kbaud to 1Mbaud (default 500 Kbaud) • Software selection of Baud rate and ID nodes • Operation with 1 or 2 settable alarm limits • “Autozero” for temperature compensation • 80% FSO calibration signal
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • SIL2 approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • SIL2 approvals for Functional Safety • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-17 ato 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: K70 series (30mm³) [0.00183 in³], K71, K72, K73 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • “Mercury free” hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH • IO-Link output, ready for “Industry 4.0” • Rangeabilty: 3:1 • PLd and SIL2 approvals for Functional safety • Autozero function • Auxiliary information over IO-Link protocol
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • SIL2 and PL d approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi (up to 400°C/750°F) • Stem material: 17-4 PH
  • Features • Alternating current solid state relay • Zero crossing switching • 15, 25, 50, 75 e 90 Arms nominal current • Non-repetitive voltage: up to 1600Vp • Nominal Voltage: up to 600 Vac • Control voltage : 3...32Vcc and 20...260Vac/ Vcc with connector • Isolation ((input-output) 4000Vrms • Green LED drive active signal
  • Features • Command input from analogue voltage or current signal or potentiometer. • Switching at voltage zero crossing. • Partialization of wave train power with dynamically optimized time cycle. • Antiparallel double SCR • 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm • 4000V isolation between input circuit and power output • MOV (varistor) • Optional monitoring of interrupted load • DIN rail mounting (standard); Panel mounting (optional)
  • Features • 4 independent loop control unit. compact, ready to use, equipped also with fieldbus interface.
  • Features • Current sizes 16, 32, 40 Amps per channel • Integrated current transformers • Fuses with fuse-holder disconnectors on the front (option) • 4 universal process inputs ( TC, RTD, mA, V ) • 4 independent hot/cold PIDs • 4 main outputs (directly connected to the static unit) • 4 auxiliary analogue inputs (option) • 4 settable outputs (option): relay/logic/TRIAC/analogue • 2 settable relay outputs • 2 settable digital inputs • Modbus RTU communication port • Communication port for Fieldbus (option): Profinet, Profibus DP, Ethernet IP, EtherCAT, Modbus TCP/RTU, CANopen, DeviceNET • ODVA (Ethernet/IP) and PI (ProfiNET) certification • DIN rail or panel mounting • CE, UL, CSA certifications and SCCR UL 508 100KA approval
  • Features
    • Independent adjustment of Max and BIAS.
    • Down-opened Panel, easy for fuse replacement.
    • VR of Max and SFS are installed in the front panel, easy for adjustment.
    • Multi-LED display panel makes the operating condition clear.
    • The auxiliary powers (AC1, AC2) are independently controlled for all models.
    • Build-in buffering output adjustment (SFS VR), adjusting range 1~22 seconds. (Only for the phase control product)
    • Top & bottom shielding covers are designed for safety and fashion out looking, also easy for wiring installation.
    • In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse burn-down
  • Principal Characteristics • The transducer is designed to satisfy extreme applicative demands in terms of mechanical strength. • The 10 mm diameter rod, large steel joints, and reinforced structure make this series mechanically ideal for Metal working, woodworking, and ceramics. • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • The structure based on self-aligning and weight-bearing ball joints permits assembly with free movement of the transducer axle
  • Features • The transducer has been improved in order to guarantee greater reliability under all conditions • Mechanical linkage using joint with take up of play, M5 thread • Installation is made simpler by the absence of electrical signal variation in output, outside the Theoretical Electrical Stroke • The new grooves provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses, vertical presses, and on many other processing machines • Grade of protection IP40
  • Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • The grooves on the profile provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses with installation at points that are highly exposed to lubricants • Also indicated for processing machines on which the transducer cannot be protected by guards
  • Applicative Characteristics • The PC67 displacement transducer was developed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the presence of dust, dirt, or liquids (not in prolonged immersion). • The robust structure of the PC series has been improved thanks to a sealing system (patent pending) that makes it extremely reliable. • Ideal for mobile hydraulic applications, on agricultural machines, earth-moving equipment and utility vehicles
  • Principal Characteristics • The transducer’s compactness makes it suitable for installation in small spaces and for detecting small shifts. • The joint with up-take of slack and M4 threading provides greater tolerances in movement. • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • Ideal for small mechanical devices, valves, and test tools and benches.
  • Principal Characteristics • The transducer’s compactness makes it suitable for installation in small spaces and for detecting small shifts. • The side connection creates a through-rod structure with double rod support, guaranteeing greater overall strength of the transducer. • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • Ideal for small mechanical devices, valves, and test tools and benches.
  • Principal Characteristics • The side connection creates a through-rod structure with double rod support, guaranteeing greater overall strength of the transducer. • The return spring automatically returns the rod to zero position, making the transducer suitable for comparator applications. • The tip with stainless steel ball is suitable for applications where the object to be measured is not subject to shifts transverse to the transducer axle. • Ideal for checking the flatness or thickness of panels of various materials. Can also be used for valves or mechanical parts when the rod cannot be attached to the moving object.
  • Principal Characteristics • The side connection creates a through-rod structure with double rod support, guaranteeing greater overall strength of the transducer. • The return spring automatically returns the rod to zero position, making the transducer suitable for comparator applications. • The tip with roller bearing is suitable for applications where the object to be measured may be subject to shifts transverse to the transducer axle (shaft is prevented from rotating). • Ideal for checking the flatness or thickness of panels of various materials. Can also be used for valves or mechanical parts when the rod cannot be attached to the moving object
  • Principal Characteristics • The 1/2” cylindrical housing, plus the option of all fastening systems (brackets, joints or flange), makes the PZ12 series highly versatile for a wide range of applications. • The optimized mechanical structure makes the product suitable for developing various special executions (contact Gefran customer service for details). • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • Ideal for wood and glass working and finishing machines and for car test benches.
  • Principal Characteristics • The 3/4” cylindrical housing, plus the option of all fastening systems (brackets, joints or flange), makes the PZ34 series highly versatile for a wide range of applications. • The optimized mechanical structure makes the product suitable for developing various special executions (contact Gefran customer service for details). • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • Ideal for wood and glass working and finishing machines and for car test benches.
  • Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • Its high protection level and very small size make the PZ67-S unique in terms of reliability and flexible installation • It is ideal for glass cutting and washing machines or for honers and sanders if there is direct exposure to liquids or even just steam • Indicated for test and bench equipment, especially if outdoors
  • Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • Its high protection level and very small size make the PZ67-A unique in terms of reliability and flexible installation • It is ideal for glass cutting and washing machines or for honers and sanders if there is direct exposure to liquids or even just steam • Indicated for test and bench equipment, especially if outdoors
  • Features • Rectilinear displacement transducer without drag shaft, completely water-tight (IP67), designed to work in humid environments (CEI EN 60529) • The PME series has an external magnetic actuator linked to an internal measurement cursor • The magnetic cursor replaces the drag shaft used in traditional displacement transducers, making the instrument even more compact • Installation is made simpler because there is no variation in the electrical output signal outside the Theoretical Electrical Stroke • The instrument can be used in compressed air applications with max. working pressure of 20 bar.

Title

Go to Top