Features
• (4 to 20) ma loop powered
• Can be used as a loop powered process switch
• Use on top of temperature probe or surface mounted
• USB and NFC interface
• Battery backup
• 5000 point data logger
• Abs plastic, stainless or aluminum housing
Features
• Accepts any DC Voltage Input Between -10 and 100VDC
• Loop Powered 4 to 20 mA Output
• Can be used as adder or subtractor
• High Accuracy
• Galvanic Isolation
Features
• Provides Extra Drive Capability From An Existing Current Loop
• Only Requires 2.7 V From the Existing Loop
• Galvanic Isolation
• High Accuracy
Features
• Provides Extra Drive Capability From An Existing Current Loop
• Dual channel
• Only Requires 2.7 V From the Existing Loop
• Galvanic Isolation
• High Accuracy
Features
• Load Cell/Strain Gauge Bridge Inputs
• (-7.5 To 7.50) Mv/ V Range, 5 V Excitation
• 2 To 6 Point Calibration
• Ratio Metric Measurement
• Remote Tare, USB Programmable
Features
• Dual or single universal frequency inputs sensor excitation
• Frequency (0.1 to 65000) Hz counter (DC TO 1000) hZ)
• Rate, totalise, k factor, m factor, maths
• Relay output
• mA, voltage, bipolar voltage output
• View live data on an Android phone or tablet
Features
• Accepts RTD, Thermocouple or Slidewire Sensors
• Current (Active or Passive), Voltage Or Bipolar Voltage Output
• Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
• 22 Segment User Linearisation
• Sensor Offset and Output Alignment
• View live data on an Android phone or tablet
Features
• Accepts Internal and External Powered Current Loops On Input and Output
• +/- 50V DC or 50 mA input
• Current, Voltage Or Bipolar Voltage Output
• Powered ( 10 to 32) V AC / (10 to 48) V DC Supply
• 22 Segment User Linearisation
• View live data on an Android phone or tablet
Features
• RTD Temperature Transmitter
• PT100, Cu100, Cu53, Ni100, Ni120
• (4 to 20) mA Two Wire Output
• Calibration and Output Trim Without a PC
• View live data on an Android phone or tablet
Features
• Dual RTD, Thermocouple, Potentiometer and mV Inputs
• Maths Functions Between Inputs
• Isolated Input to Output 4kV DC Flash Tested
• SIL Hardware Safety Integrity
Features
• Pt100,Thermocouple,mV,mA Input
• (0 to 10), (0 to 5), (2 to 10), (1 to 5) and ( 0 to 1)V DC Programmable output
• Push Button User Trim For In Process Fine Tuning
• Galvanic Isolation
• View live data on an Android phone or tablet
Features
• Pt100, Thermocouple, mA, mV input
• Dual Relay Outputs 250V AC @ 1A
• Relay Contacts isolated from each other
• Galvanic Isolation
• View live data on an Android phone or tablet
Features
• Dual Change Over Relay Output
• Relay Rating 250V AC 1A; 30V DC 1A
• Latching Relays In Case Of Loop Failure
• Powered From 4/20mA Loop
• LED Alarm Indication
• View live data on an Android phone or tablet
Features
• RTD, Thermocouple, mV, V, mA and Potentiometer Input
• Isolated Universal Voltage or Current Output
• Dual C/O Relay Trip Outputs
• Universal Power Requirement 22 to 250V AC or DC
• Powers both input and output current loops
• SIL Approval
• View live data on an Android phone or tablet
Features
• Dual Channel With 5 Port Isolation (3.75Kv)
• Accepts RTD, Thermocouple or Potentiometer Sensors
• Universal Voltage Or Current Outputs
• Maths Functions Between Channels
• Sensor Redundancy Switching
• Eight User Configured Preset Configurations
Features
• Dual Channel Voltage Or Current (Active/Passive)Inputs and Outputs
• 5 Port Isolation To 3.75Kv
• Can Be Configured As An Active Signal Splitter
• User Selectable Maths Functions On Each Output Channel
• Signal Linearisation
• Signal Simulate Function For Diagnostics
Features
• Instrinsically Safe for hazardous area use
• PT100, Cu100, Cu53, Ni100, Ni120 sensor options
• Single or dual channel
• 22 Segment user linearization for input
• Sensor offset and output alignment
• PC configurable
Features
• Instrinsically Safe for hazardous area use
• Loop powered
• K, J, N, E, T, R, S, L, U, B, C(W5), D(W3), G(W) type Thermocouples
• Single or dual channel
• Sensor offset and output alignment
• PC configurable
Features
• Suitable for thermocouple and mv sensors
• (4 to 20) ma output
• Pc programmable input type and range
• High stability
• Output current trim
Features
• Suitable for variable resistance sensors (1 to 100) kΩ
• Unique push button configuration
• Push button configuration
• < 50 Ms Response Time
• 2 Wire (4 To 20) Ma Loop Powered
Features
• Suitable for pt100 temperature sensors
• (4 to 20) ma output
• PC programmable temperature range
• Sensor referencing
• Sensor burn out detection
• Free configuration software
• High stability
Features
• Suitable for thermocouple sensors
• (4 to 20) ma output
• PC programmable input type and range
• Free configuration software
• Sensor referencing
• Sensor burn out detection
• High stability