Loading...
  • Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • The grooves on the profile provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses with installation at points that are highly exposed to lubricants • Also indicated for processing machines on which the transducer cannot be protected by guards
  • Features • The transducer has been improved in order to guarantee greater reliability under all conditions • A sturdier structure makes the LT series even stronger for applications with heavy vibration • Installation is made simpler by the absence of electrical signal variation in output, outside the Theoretical Electrical Stroke • The new grooves provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses, vertical presses, and on many other processing machines
  • Features • For use in most aqueous alkaline solutions, plating and phosphate tanks. Check solution recommendation chart with your chemical supplier for proper sheath material selection. • Heavy wall metal sheaths available in: steel, 304 stainlesss steel, 316 stainless steel, titanium. • Watt densities up to 18 watts per square inch (2.8 w/cm²) ensure long service life. • Vapor-resistant, flame retardant polypropylene termimal enclosure with 3 ft (.9m) flexible PVC liquid tight conduit. • Temperature and level controls sized to match the heater. • Lower watt densities for highly viscous solutions.
  • Features • Ranges: from 1 to 1000 bar • Nominal Output Signal: 4...20mA (2 wires) 0...10Vdc / 0.1...5.1Vdc / 0.1...10.1Vdc / 0...5Vdc / 1...5Vdc / 1...6Vdc / 1...10Vdc / 0.2...10.2Vdc (3 wires) 0.5...4.5Vdc (3 wires - ratiometric) • Compact size • Wetted parts: Stainless steel • SIL 2 certified according to IEC/EN 62061:2005
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: KN0 series (30mm3) [0.00183 in3], KN1, KN2, KN3 (40mm3) [0.00244 in3] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features • J1939 and CANOpen digital signal output • All stainless steel construction • Pressure ranges up to 1000 bar
  • Features • J1939 and CANOpen digital signal output • All stainless steel construction • Pressure ranges up to 1000 bar
  • Features • Ranges: from 4 to 1000 bar • Nominal Output Signal: 0...10Vdc (3 wires) / 4...20mA (2 wires) 0.5...4.5 v ratiometric • Compact size • Wetted parts: Stainless steel • SIL 2 certified according to IEC/EN 62061:2005
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • SIL2 approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features Electrical • Digital output signal with DP404 CAN OPEN communication protocol • Transmission frequency (Baud rate): 10 Kbaud to 1Mbaud (default 500 Kbaud) • Software selection of Baud rate and ID nodes • Operation with 1 or 2 settable alarm limits • “Autozero” for temperature compensation • 80% FSO calibration signal
  • Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • SIL2 approvals for Functional Safety • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features • Pressure ranges from: 0-17 ato 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: K70 series (30mm³) [0.00183 in³], K71, K72, K73 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
  • Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy <±0.25% FSO (H); <±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS • Quantity of NaK contained per model: K30 series (30mm³) [0.00183 in³], K31-K32-K33 series (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
  • Features
    • NO and NC in one casing
    • Separate adjustable temperature
    • High switching capacity
    • Terminal easily accessible
    • Clip fixing
  • Features
    • Large Setting Range
    • Small Size
    • Simple to Mount
    • High Switching Performance
  • Features
    • Large Setting Range
    • Small Size
    • Simple to Mount
    • High Switching Performance
  • Features • Compact design • Double insulated • Integrated thermostat or hygrostat • Optional clip or screw fixing
  • Features • Compact heater • Integrated thermostat • Clip fixing • Optical Indicator • Temperature safety cut-out
  • Features • Compact design • DIN-Rail Mounting
  • Features • Ball bearing fan heater ensures long life • compact design • Aluminum case • IP20 Protection • internal connection piece
  • Features • Aluminum case • IP20 Protection
  • Features
    • This product senses the temperature in the air easily because of the spiral shaped sensor
    • Temperature Range:  0°C ~ 50°C
  • Features • Up to 16 inputs/16 outputs • For Temperature, Pressure, Flow, Level, RH, Conductivity, etc. • Various Input (X)/Output (Y) combinations : X4Y0, X4Y8, X8Y4, X8Y16, X16Y16, etc • Universal Input : 8 Thermocouples, Pt100, mV or mA input front panel selection without DIP for each channel • Front panel user calibration • Input burn protection • Non-volatile memory for parameters - no batteries • 3 key, 5 level programming • Setpoint and level locks • Tactile membrane keypad • 5 software versions : Indicator, Multisetpoint, Grouping, etc • RS485 with MODBUS RTU • Powerful, flexible SCADA software available • FDA21CFR Part11 compliant SCADA version also • Option : Printer interface (no computer needed) • 85~265 V AC SMPS or 24 V DC supply
  • Features • Upto 16 inputs/16 outputs • For Temperature, Pressure, Flow, Level, RH, Conductivity, etc. • Various Input (X)/Output (Y) combinations : X4Y0, X4Y8, X8Y4, X8Y16, X16Y16, etc • Universal Input : 8 Thermocouples, Pt100, mV or mA input front panel selection without DIP for each channel • Front panel user calibration • Input burn protection • Non-volatile memory for parameters - no batteries • 3 key, 5 level programming • Setpoint and level locks • Tactile membrane keypad • 5 software versions : Indicator, Multisetpoint, Grouping, etc • RS485 with MODBUS RTU • Powerful, flexible SCADA software available • FDA21CFR Part11 compliant SCADA version also • Option : Printer interface (no computer needed) • 85~265 V AC SMPS or 24 V DC supply

Title

Go to Top