-
Principal Characteristics • The PMA-12 transducer, a development of the PME series, is designed for installation with self-aligning joints. • The IP67 protection level makes the PMA-12 highly suitable for humid and wet environments and in temporary immersion (CEI EN 60529). • Available only with cable output. • Ideal for applications on metalworking and ceramics machines, as well as on earth-moving machines and utility vehicles. Recommended in all cases where the angle of the drive axle changes constantly.
-
Main Characteristics • The PMI-12 transducer is designed for use inside oil pressure cylinders, applications that demand high strength. • The AISI316 stainless steel body and elevated protection level permit installation in cylinders with pressures up to 250 bar (400 bar peak). • Available with internal flanges or external threads to guarantee mechanical compatibility with all principal cylinder types. • Patented
-
Applicative Characteristics • The PMI-SL transducer, an evolution of the PMI-12, is designed for all inside cylinder applications which require a smaller transducer. For this reason, the diameter has been reduced to 12.7 mm. • The PMI Slim offers the same robustness as the PMI-12: AISI 316 stainless steel body, IP67 protection level, and pressure resistance up to 250 bar (400 bar peak) • Available with flanged or threaded heads, to guarantee mechanical compatibility with all main cylinder types • Patented solution • Ideal for applications inside hydraulic cylinders, demanding simple solutions which guarantee measurement repeatability
-
Applicative Characteristics • The PMI-SLE transducer, is the amplified version of the PMI-SL, a product designed for all inside cylinder applications which require a smaller transducer (the rod diameter is only 12,7 mm). • The PMI Slim offers the same robustness: stainlessteel body, IP67 protection level, and pressure resistance up to 250 bar (400 bar peak) • Available with flanged or threaded heads, to guarantee mechanical compatibility with all main cylinder types • Patented solution • Ideal for applications inside hydraulic cylinders, demanding simple solutions which guarantee measurement repeatability.
-
Principal Characteristics • Transducer with exposed tracks, allowing rod diameter is reduced to be reduced to a minimum to permit installation in small cylinders. • Thanks to a special constructive technique, the IC transducer provides high resistance to the working pressures of oil-pressure cylinders (max 340 bar) • Available with internal flanges or external threads to guarantee mechanical compatibility with all principal cylinder types.
-
Features • Models 09, 11, 20 • Servo mounting • Independent linearity up to ± 0,05% (standard ± 0,5%) • Repetibility 0,01% C.E.T. • Rotation speed ≤ 600 r.p.m. (within C.E.U.) • Life duration: >100x106 operations at 10 r.p.s. • Infinite resolution • Electrical terminals: turrets • Grade of protection IP40 • Suitable for use in explosive environments with presence of gas (groups IIA, IIB, IIC) and combustible powders. Standards for simple device: ATEX CEI EN 50020 2003 - paragraph 5.4 a
-
Features • Sealed industrial version • Independent linearity up to ± 0,05% (standard ± 0,5%) • Working temperature: -55...+100°C • Repetibility 0,01% della C.E.T. • Life duration: >100x106 operations at 10 r.p.s. (within C.E.U.) • Infinite resolution • Electrical connection: 5-pole connector DIN 43322 • Grade of protection IP65 • Suitable for use in explosive environments with presence of gas (groups IIA, IIB, IIC) and combustible powders. Standards for simple device: ATEX CEI EN 50020 2003 - paragraph 5.4 a
-
Features • Interface module integrated in the connector • Standard output 0...10Vdc (PCIR 101) • Standard output 4...20mA(PCIR 102) • High linearity • Adjustable Zero and Span • Low zero and span thermal drift • 4 pole female DIN43650 connector for LTM and PKM potentiometer • DIN 43650 4-pin female connector for direct connection to LTM and PKM potentiometers (the DIN 43650 connector in the PCM series is smaller and cannot be connected directly)
-
Features • Integrated 3 sensors in 1 device with LCD display • Measuring temperature, humidity and carbon dioxide • 2 analog outputs and Modbus RS-485 • Optional analog output + RS-485 • Quick easy installation and maintenance due to well designed • Cost-efficient and reliable • Data can be logged and transferred to PC via RS-485 function link free software
-
Features • IP67, Stainless steel SUS304, Pressure resistance 16 bar • 330° rotatable, lightweight, unrestricted installation • Optional on-site real-time display • Process temperature up to 180°C, custom up to 200°C (Optional) • Output:Analog / RS-485 • Wide measurement range, Temp. : -40 ... +180°C, Humidity : 0 ... 100%RH • Measuring parameter:relative humidity, dew point temperature, frost point temperature, wet-bulb temperature, vapor pressure, mixture ratio, absolute humidity and specific enthalpy.
-
Features • Industrial sensor comes with high accuracy and long-term stability • Capable of temperature compensation and linear calibration • 2 analog output or Modbus RS-485 • Optional analog output + RS-485 • Probe:PC • Power supply:DC 8 ... 35 V and AC 12 ... 30 VRS-485 and Modbus RTU • Free programmable software - Physical quantities / Output / Data logger / Charts / Calibration
-
Features • IP65 , rugged aluminum case, fit in variety harsh environment • Capable of temperature compensation. Linear adjustment temperature & humidity by computer, analog output or option RS-485 • Measure high accuracy Temp. & humidity, reaction quickly, the sensor can work well after temporary condensation, long term stable in high humidity environment • Process Temp. : up to 200°C, S.S. probe proof pressure : 10 bar, metal connector : installation repeatedly • Switch multifunction physical quantities:[%RH]、[°C]、[mbar]、[g/kg]、[g/m3]、[kj/kg] • Calibration physical quantities, measuring range, analog output, station, etc • Free calibration software : data logger / record 65535 datas / charts
-
Features • Dew point calibration, highly accuracy, 4 ... 20 mA and RS-485 output • Reduce insensitivity temperature zone, quickly response • Hysteresis compensation, resistance to moisture, extreme high and low humidity impact • EMC anti-interference, anti-condensation, low-temperature influence, long-term stability • Three thread (1/2″PT, 1/2″G, and 5/8″UNF) mode can be selected
-
Features
- MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package
- Stable firmware based on Linux
- 13 available input/output blocks
- Colour LCD display 3,5" TFT, with touchscreen
- Recording data with maximum speed 10Hz (ten samples per second)
- 2 or 4 GB internal data memory
- RS-485 (Modbus RTU), USB Host, Ethernet communication
- Wall mounted IP 65 case
-
Features
- MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package
- stable firmware based on Linux
- 27 available input/output modules
- 60 logical channels
- colour LCD display 3.5" TFT, with touchscreen
- recording data with maximum speed 10Hz (ten samples per second)
- 2 or 4 GB internal data memory
- RS-485 (Modbus RTU), USB Host, Ethernet communication
- panel, compact device in 96 x 96 mm case
-
Features
- MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package
- stable firmware based on Linux
- 41 available input/output modules
- 90 logical channels
- colour LCD display 5.7" TFT, with touchscreen
- recording data with maximum speed 10Hz (ten samples per second)
- 2 or 4 GB internal data memory
- RS-485 (Modbus RTU), USB Host, Ethernet communication
- panel, compact device in 144 x 144 mm case
-
Features • Operator interface with color touch screen display, 3.5 “ • Up to 8 PID control loops • Cascade, ratio and valve PID controls • Profile programmer with ramps and retention; synchronous and asynchronous • Up to 200 Programs with 50 segments • 3 password protected user levels • Energy meter (kWh) • Configurable logic operations • Configurable math functions • Data Log with Real Time Clock • Batch Report management • Open format files (CSV) or encrypted for DataLog and production batches • Setting up custom pages • Management of active and historic alarms • Active and historical alarm management • USB for data export and parameter cloning • Control parameter advanced tuning • Configurable analogue and digital I/O signals • HMI/SCADA/PLC data exchange via Ethernet Modbus TCP • Message language selection
-
Features • Operator interface with color touch screen display, 7” • Up to 16 PID control loops • Cascade, ratio and valve PID controls • Profile programmer with ramps and retention; synchronous and asynchronous • Up to 250 Programs with 50 segments • 3 password protected user levels • Energy meter (kWh) • Configurable logic operations • Configurable math functions • Data Log with Real Time Clock • Batch Report management • Open format files (CSV) or encrypted for DataLog and production batches • Setting up custom pages • Active and historical alarm management • USB for data export and parameter cloning • Control parameter advanced tuning • Configurable analogue and digital I/O signals • HMI/SCADA/PLC data exchange via Ethernet Modbus TCP • Message language selection
-
Features • Multi-input and multi-range performance • Small instrument depths (62mm - 65mm) save space, thus securing a larger installation area. • SV setting: 3 points • PID Value: 3 types • 2-output heating and cooling control available (optional) • Total 32 steps Program available (optional) (1-4 pattern, 32-8 step) • RS-485 Interface available (optional) (Master/slave function, Modbus/Shimaden Protocol) • Heater break/heater loop alarm (optional) • A wide selection of additional functions (optional) is available to suit various needs. • Possible to switch off SV/PV value by key operation • Parameter mask (non-display) / lock (key lock) function
-
Features • Multi-input and multi-range performance • Small instrument depths (62mm - 65mm) save space, thus securing a larger installation area. • SV setting: 3 points • PID Value: 3 types • 2-output heating and cooling control available (optional) • Total 32 steps Program available (optional) (1-4 pattern, 32-8 step) • RS-485 Interface available (optional) (Master/slave function, Modbus/Shimaden Protocol) • Heater break/heater loop alarm (optional) • A wide selection of additional functions (optional) is available to suit various needs. • Possible to switch off SV/PV value by key operation • Parameter mask (non-display) / lock (key lock) function
-
Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac , continuous, digital insulated • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line. Protocol: GEFRAN CENCAL or MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
-
Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac , continuous, digital insulated • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line.Protocol: GEFRAN CENCAL or MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
-
Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac or continuous • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Up to 2 isolated digital inputs with configurable function • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line. Protocol: GEFRAN MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
-
Features • 2-channel controller (Basic type: 1-channel controller) • Independent 2-loop / Internal Cascade / 2-input operation control • High accuracy ± (0.1% FS + 1 digit) • High Sampling Cycle 0.1 sec. • High resolution 1/ 1000 °C display achieved *Only for R.T.D. input (scale: 0.000~30.000 °C) • Auto-Tuning PID / Expert PID / Self-Tuning PID • Multi-Setting of 10 Set Values • Independent Universal-Input • User Friendly Operation (Menu Driven: 4 Lines LCD Display) • Easy Setting & Maintenance via Infrared COM port on the front panel • Interface RS-232C/RS-485 (MODBUS / Shimaden) • The front dust/splash-proof IP66 • Universal Power Supply (100~240V AC ±10%) • Sensor power supply
-
Features • 3-channel controller, 3-channel input, 3-channel setting and simultaneous 3-channel display are possible • Accuracy: ± (0.3% FS + 1 digit) • Follow-up type PV input function • Follow-up type SV setting function • Remote/local and DI input function • Programmable 1 pattern with 9-step function • Included a new processing system, Expert PID, remarkably improved PID control efficiency; overshoot and undershoot are controlled effectively. • Interface RS232C/RS485
-
Features • 2-channel controller (Basic type: 1-channel controller) • Independent 2-loop / 2-input operation control • High accuracy ± (0.1% FS + 1 digit) • High Sampling Cycle 0.1 sec. • High resolution 1/ 1000 °C display achieved *Only for R.T.D. input (scale: 0.000~30.000 °C) • Programmable Max. 400 steps (400 steps x 1 pattern to 20 steps x 20 patterns) • Auto-Tuning PID / Expert PID • Max. 10 Zone PID control available • Independent Universal-Input • User Friendly Operation (Menu Driven: 4 Lines LCD Display) • Easy Setting & Maintenance via Infrared COM port on the front panel • Interface RS-232C/RS-485 (MODBUS / Shimaden) • The front dust/splash-proof IP66 • Universal Power Supply (100~240V AC ±10%) • Sensor power supply
-
Features • Operator interface with large LCD Display, customizable, with choice of colors • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even with power off • Preventive maintenance with energy counters (kWh) and load switching • 16 function block applications • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • Universal input configurable for thermocouples, resistance thermometers, linear inputs • Remote set point input • Relay, logic, isolated analog outputs • Up to two CT inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU • Removable faceplate for immediate replacement • Sampling time 60ms
-
Features • Operator interface with large LCD Display and three configurable bargraphs • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even withe power off • Preventive maintenance with energy counters (kWh) and load switching • 32 function block applications • 8 Math application blocks • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • 2 Universal inputs configurable for thermocouples, resistance thermometers, linear inputs • 1 linear analog input configurable for auxiliary functions • 2 PID control loops • 2 set point programmers (192 steps in 16 programs, or 12 programs with 16 fixed steps each) • Relay, logic, isolated analog outputs • Up to two TA inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU slave • RS485 serial communication in Modbus RTU master for reading/ writing information to Modbus slave devices • Ethernet Modbus TCP communication in Slave mode • Web server for browser access to web pages residing in the device, for monitoring and setting parameters • Bridge function for creation of Modbus RTU 485 sub-network • Weekly clock\calendar with RTC • Removable faceplate for immediate replacement • Accuracy 0,1%, sampling time 60 ms
-
Features
- Operator interface with large LCD Display, customizable, with choice of colors
- Scrolling diagnostics messages, configurable, in the selected language
- Easy, guided configuration, copy/paste parameters even with power off
- Preventive maintenance with energy counters (kWh) and load switching
- 16 function block applications
- Timer, setpoint and algorithm programmer for controlling motorized valves
- Advanced tuning of control parameters
- Different password levels
- Universal input configurable for thermocouples, resistance thermometers, linear inputs
- Remote setpoint input
- Relay, logic, isolated analog outputs
- Up to two CT inputs for interrupted load diagnostics
- RS485 serial communication in Modbus RTU
- Removable faceplate for immediate replacement
- Sampling time 60ms
-
Features • Operator interface with large LCD Display, customizable, with choice of colors • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even with power off • Preventive maintenance with energy counters (kWh) and load switching • 16 function block applications • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • Universal input configurable for thermocouples, resistance thermometers, linear inputs • Remote set point input • Relay, logic, isolated analog outputs • Up to two CT inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU • Removable faceplate for immediate replacement • Sampling time 60ms