-
Features • The transducer has been improved in order to guarantee greater reliability under all conditions • A sturdier structure makes the LT series even stronger for applications with heavy vibration • Installation is made simpler by the absence of electrical signal variation in output, outside the Theoretical Electrical Stroke • The new grooves provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses, vertical presses, and on many other processing machines
-
Features • Measurement range: ±180° different values on request programmable in steps of ±15° (ONLY for analogue versions) • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +9…+36Vdc (see output signal for right supply voltage) • Output signal : 0.5...4.5V Ratiometric (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen, SAE J1939 • Electrical connections: AMP Superseal 6P 282108-1; DEUTSCH 6P DT04-6P • Resolution and speed of rotation: 12 bit (analog output); 14 bit (CANopen/SAE J1939 output); 120 rpm max. • Linearity: < ± 0.5% FS • Working and coefficient temperature: -40°C ... +85°C (higher values on request); thermal drift < 50 ppm/°C
-
Features • Measurement range: ±180° - different values on request programmable in steps of ±15° (ONLY for analogue versions) • Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +9…+36Vdc (see output signal for right supply voltage) • Output signal: 0.5...4.5V RATIOMETRIC (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen, SAE J1939 • Electrical connections: AMP Superseal 6P 282108-1; cable output 18 AWG 1.65mm OD • Resolution and speed of rotation: 12 bit (analog output); 14 bit (CANopen/SAE J1939 output); 120 rpm max. • Linearity: < ±0.5%FS • Working and coefficient temperature: -40°C ... +85°C (higher values on request); thermal drift < 50 ppm/°C
-
Features
- Measurement range : ±10° ±15° ±20° ±30° ±45° ±60° ±85° (dual axis XY); 360° (±180°) (single axis Z)
- Supply voltage: +5Vdc (only for 0.5..4.5Vdc output); +10…+36Vdc (see output signal for right supply voltage)
- Output signal: 0.5...4.5V RATIOMETRIC (supply +5Vdc); 0.5...4.5V; 0...10V; 4...20mA; CANopen
- Electrical connections: AMP Superseal 6P 282108-1; 6 wires output 18 AWG 1.65mm OD (cable+connector on request)
- Resolution: 0.05° (±10° to ±20°); 0.05°(±30°); 0.1°(±45°); 0.1°(±60°); 0.1°(±85°); 0.1° (±180°) analog output; 0.05° CANopen output
-
Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
-
Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy <±0.25% FSO (H); <±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS • Quantity of NaK contained per model: K30 series (30mm³) [0.00183 in³], K31-K32-K33 series (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
-
Features • Pressure ranges from: 0-35 to 0-1000 bar / 0-500 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: KN0 series (30mm3) [0.00183 in3], KN1, KN2, KN3 (40mm3) [0.00244 in3] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
-
Features Electrical • Digital output signal with DP404 CAN OPEN communication protocol • Transmission frequency (Baud rate): 10 Kbaud to 1Mbaud (default 500 Kbaud) • Software selection of Baud rate and ID nodes • Operation with 1 or 2 settable alarm limits • “Autozero” for temperature compensation • 80% FSO calibration signal
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • SIL2 approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • SIL2 approvals for Functional Safety • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Stem drift Auto compensation function (SP version) • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS) • Quantity of NaK contained per model: KE0 series (30mm³) [0.00183 in³], KE1, KE2, KE3 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH
-
Features • Pressure ranges from: 0-17 ato 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FSO (H); < ±0.5% FSO (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). Liquid conforming to RoHS Directive. NaK is defined as a safe substance (GRAS). • Quantity of NaK contained per model: K70 series (30mm³) [0.00183 in³], K71, K72, K73 (40mm³) [0.00244 in³] • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100 bar-1500 psi up to 400°C (750°F) • Material of stem 17-4PH
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • “Mercury free” hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi up to 400°C (750°F) • Stem material: 17-4 PH • IO-Link output, ready for “Industry 4.0” • Rangeabilty: 3:1 • PLd and SIL2 approvals for Functional safety • Autozero function • Auxiliary information over IO-Link protocol
-
Features • Pressure ranges from: 0-17 to 0-1000 bar / 0-250 to 0-15000 psi • Accuracy: < ±0.25% FS (H); < ±0.5% FS (M) • Hydraulic transmission system for pressure signal guarantees stability at working temperature (NaK). • SIL2 and PL d approvals for Functional Safety • 1/2-20UNF, M18x1.5 standard threads; other types available on request • Autozero function on board / external option • Inconel 718 diaphragm with GTP+ coating for temperatures up to 538°C (1000°F) • 15-5 PH diaphragm with GTP+ coating for temperatures up to 400°C (750°F) • Hastelloy C276 diaphragm for temperatures up to 300°C (570°F) • 17-7 PH corrugated diaphragm with GTP+ coating for ranges below 100bar-1500psi (up to 400°C/750°F) • Stem material: 17-4 PH
-
Features • Alternating current solid state relay • Zero crossing switching • 15, 25, 50, 75 e 90 Arms nominal current • Non-repetitive voltage: up to 1600Vp • Nominal Voltage: up to 600 Vac • Control voltage : 3...32Vcc and 20...260Vac/ Vcc with connector • Isolation ((input-output) 4000Vrms • Green LED drive active signal
-
Features • Command input from analogue voltage or current signal or potentiometer. • Switching at voltage zero crossing. • Partialization of wave train power with dynamically optimized time cycle. • Antiparallel double SCR • 2 led for supply indication, “ON” state, 1 optional LED for load interrupt alarm • 4000V isolation between input circuit and power output • MOV (varistor) • Optional monitoring of interrupted load • DIN rail mounting (standard); Panel mounting (optional)
-
Features • Current sizes 16, 32, 40 Amps per channel • Integrated current transformers • Fuses with fuse-holder disconnectors on the front (option) • 4 universal process inputs ( TC, RTD, mA, V ) • 4 independent hot/cold PIDs • 4 main outputs (directly connected to the static unit) • 4 auxiliary analogue inputs (option) • 4 settable outputs (option): relay/logic/TRIAC/analogue • 2 settable relay outputs • 2 settable digital inputs • Modbus RTU communication port • Communication port for Fieldbus (option): Profinet, Profibus DP, Ethernet IP, EtherCAT, Modbus TCP/RTU, CANopen, DeviceNET • ODVA (Ethernet/IP) and PI (ProfiNET) certification • DIN rail or panel mounting • CE, UL, CSA certifications and SCCR UL 508 100KA approval
-
Features
- Independent adjustment of Max and BIAS.
- Down-opened Panel, easy for fuse replacement.
- VR of Max and SFS are installed in the front panel, easy for adjustment.
- Multi-LED display panel makes the operating condition clear.
- The auxiliary powers (AC1, AC2) are independently controlled for all models.
- Build-in buffering output adjustment (SFS VR), adjusting range 1~22 seconds. (Only for the phase control product)
- Top & bottom shielding covers are designed for safety and fashion out looking, also easy for wiring installation.
- In case of 0.5 Hz sudden power losses, system output can be switched off immediately. Once the power is restored, the system will buffer the output to prevent the voltage surge for fuse burn-down
-
Principal Characteristics • The transducer is designed to satisfy extreme applicative demands in terms of mechanical strength. • The 10 mm diameter rod, large steel joints, and reinforced structure make this series mechanically ideal for Metal working, woodworking, and ceramics. • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • The structure based on self-aligning and weight-bearing ball joints permits assembly with free movement of the transducer axle
-
Features • The transducer has been improved in order to guarantee greater reliability under all conditions • Mechanical linkage using joint with take up of play, M5 thread • Installation is made simpler by the absence of electrical signal variation in output, outside the Theoretical Electrical Stroke • The new grooves provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses, vertical presses, and on many other processing machines • Grade of protection IP40
-
Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • The grooves on the profile provide an excellent alternative to the usual system of fastening with brackets • Ideal for applications on plastic injection presses with installation at points that are highly exposed to lubricants • Also indicated for processing machines on which the transducer cannot be protected by guards
-
Applicative Characteristics • The PC67 displacement transducer was developed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the presence of dust, dirt, or liquids (not in prolonged immersion). • The robust structure of the PC series has been improved thanks to a sealing system (patent pending) that makes it extremely reliable. • Ideal for mobile hydraulic applications, on agricultural machines, earth-moving equipment and utility vehicles
-
Principal Characteristics • The transducer’s compactness makes it suitable for installation in small spaces and for detecting small shifts. • The joint with up-take of slack and M4 threading provides greater tolerances in movement. • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • Ideal for small mechanical devices, valves, and test tools and benches.
-
Principal Characteristics • The transducer’s compactness makes it suitable for installation in small spaces and for detecting small shifts. • The side connection creates a through-rod structure with double rod support, guaranteeing greater overall strength of the transducer. • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • Ideal for small mechanical devices, valves, and test tools and benches.
-
Principal Characteristics • The side connection creates a through-rod structure with double rod support, guaranteeing greater overall strength of the transducer. • The return spring automatically returns the rod to zero position, making the transducer suitable for comparator applications. • The tip with stainless steel ball is suitable for applications where the object to be measured is not subject to shifts transverse to the transducer axle. • Ideal for checking the flatness or thickness of panels of various materials. Can also be used for valves or mechanical parts when the rod cannot be attached to the moving object.
-
Principal Characteristics • The side connection creates a through-rod structure with double rod support, guaranteeing greater overall strength of the transducer. • The return spring automatically returns the rod to zero position, making the transducer suitable for comparator applications. • The tip with roller bearing is suitable for applications where the object to be measured may be subject to shifts transverse to the transducer axle (shaft is prevented from rotating). • Ideal for checking the flatness or thickness of panels of various materials. Can also be used for valves or mechanical parts when the rod cannot be attached to the moving object
-
Principal Characteristics • The 1/2” cylindrical housing, plus the option of all fastening systems (brackets, joints or flange), makes the PZ12 series highly versatile for a wide range of applications. • The optimized mechanical structure makes the product suitable for developing various special executions (contact Gefran customer service for details). • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • Ideal for wood and glass working and finishing machines and for car test benches.
-
Principal Characteristics • The 3/4” cylindrical housing, plus the option of all fastening systems (brackets, joints or flange), makes the PZ34 series highly versatile for a wide range of applications. • The optimized mechanical structure makes the product suitable for developing various special executions (contact Gefran customer service for details). • Installation is simplified by the lack of electrical signal variation at output outside theoretical electrical stroke. • Ideal for wood and glass working and finishing machines and for car test benches.
-
Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • Its high protection level and very small size make the PZ67-S unique in terms of reliability and flexible installation • It is ideal for glass cutting and washing machines or for honers and sanders if there is direct exposure to liquids or even just steam • Indicated for test and bench equipment, especially if outdoors
-
Features • This transducer is designed to guarantee a high protection level (IP67) in applications under harsh conditions and outdoors, where it may be necessary to work in the direct presence of dust, dirt, or liquids (not in prolonged immersion) • Its high protection level and very small size make the PZ67-A unique in terms of reliability and flexible installation • It is ideal for glass cutting and washing machines or for honers and sanders if there is direct exposure to liquids or even just steam • Indicated for test and bench equipment, especially if outdoors
-
Features • Rectilinear displacement transducer without drag shaft, completely water-tight (IP67), designed to work in humid environments (CEI EN 60529) • The PME series has an external magnetic actuator linked to an internal measurement cursor • The magnetic cursor replaces the drag shaft used in traditional displacement transducers, making the instrument even more compact • Installation is made simpler because there is no variation in the electrical output signal outside the Theoretical Electrical Stroke • The instrument can be used in compressed air applications with max. working pressure of 20 bar.
-
Principal Characteristics • The PMA-12 transducer, a development of the PME series, is designed for installation with self-aligning joints. • The IP67 protection level makes the PMA-12 highly suitable for humid and wet environments and in temporary immersion (CEI EN 60529). • Available only with cable output. • Ideal for applications on metalworking and ceramics machines, as well as on earth-moving machines and utility vehicles. Recommended in all cases where the angle of the drive axle changes constantly.
-
Main Characteristics • The PMI-12 transducer is designed for use inside oil pressure cylinders, applications that demand high strength. • The AISI316 stainless steel body and elevated protection level permit installation in cylinders with pressures up to 250 bar (400 bar peak). • Available with internal flanges or external threads to guarantee mechanical compatibility with all principal cylinder types. • Patented
-
Applicative Characteristics • The PMI-SL transducer, an evolution of the PMI-12, is designed for all inside cylinder applications which require a smaller transducer. For this reason, the diameter has been reduced to 12.7 mm. • The PMI Slim offers the same robustness as the PMI-12: AISI 316 stainless steel body, IP67 protection level, and pressure resistance up to 250 bar (400 bar peak) • Available with flanged or threaded heads, to guarantee mechanical compatibility with all main cylinder types • Patented solution • Ideal for applications inside hydraulic cylinders, demanding simple solutions which guarantee measurement repeatability
-
Applicative Characteristics • The PMI-SLE transducer, is the amplified version of the PMI-SL, a product designed for all inside cylinder applications which require a smaller transducer (the rod diameter is only 12,7 mm). • The PMI Slim offers the same robustness: stainlessteel body, IP67 protection level, and pressure resistance up to 250 bar (400 bar peak) • Available with flanged or threaded heads, to guarantee mechanical compatibility with all main cylinder types • Patented solution • Ideal for applications inside hydraulic cylinders, demanding simple solutions which guarantee measurement repeatability.
-
Principal Characteristics • Transducer with exposed tracks, allowing rod diameter is reduced to be reduced to a minimum to permit installation in small cylinders. • Thanks to a special constructive technique, the IC transducer provides high resistance to the working pressures of oil-pressure cylinders (max 340 bar) • Available with internal flanges or external threads to guarantee mechanical compatibility with all principal cylinder types.
-
Features • Models 09, 11, 20 • Servo mounting • Independent linearity up to ± 0,05% (standard ± 0,5%) • Repetibility 0,01% C.E.T. • Rotation speed ≤ 600 r.p.m. (within C.E.U.) • Life duration: >100x106 operations at 10 r.p.s. • Infinite resolution • Electrical terminals: turrets • Grade of protection IP40 • Suitable for use in explosive environments with presence of gas (groups IIA, IIB, IIC) and combustible powders. Standards for simple device: ATEX CEI EN 50020 2003 - paragraph 5.4 a
-
Features • Sealed industrial version • Independent linearity up to ± 0,05% (standard ± 0,5%) • Working temperature: -55...+100°C • Repetibility 0,01% della C.E.T. • Life duration: >100x106 operations at 10 r.p.s. (within C.E.U.) • Infinite resolution • Electrical connection: 5-pole connector DIN 43322 • Grade of protection IP65 • Suitable for use in explosive environments with presence of gas (groups IIA, IIB, IIC) and combustible powders. Standards for simple device: ATEX CEI EN 50020 2003 - paragraph 5.4 a
-
Features • Interface module integrated in the connector • Standard output 0...10Vdc (PCIR 101) • Standard output 4...20mA(PCIR 102) • High linearity • Adjustable Zero and Span • Low zero and span thermal drift • 4 pole female DIN43650 connector for LTM and PKM potentiometer • DIN 43650 4-pin female connector for direct connection to LTM and PKM potentiometers (the DIN 43650 connector in the PCM series is smaller and cannot be connected directly)
-
Features • Integrated 3 sensors in 1 device with LCD display • Measuring temperature, humidity and carbon dioxide • 2 analog outputs and Modbus RS-485 • Optional analog output + RS-485 • Quick easy installation and maintenance due to well designed • Cost-efficient and reliable • Data can be logged and transferred to PC via RS-485 function link free software
-
Features • IP67, Stainless steel SUS304, Pressure resistance 16 bar • 330° rotatable, lightweight, unrestricted installation • Optional on-site real-time display • Process temperature up to 180°C, custom up to 200°C (Optional) • Output:Analog / RS-485 • Wide measurement range, Temp. : -40 ... +180°C, Humidity : 0 ... 100%RH • Measuring parameter:relative humidity, dew point temperature, frost point temperature, wet-bulb temperature, vapor pressure, mixture ratio, absolute humidity and specific enthalpy.
-
Features • Industrial sensor comes with high accuracy and long-term stability • Capable of temperature compensation and linear calibration • 2 analog output or Modbus RS-485 • Optional analog output + RS-485 • Probe:PC • Power supply:DC 8 ... 35 V and AC 12 ... 30 VRS-485 and Modbus RTU • Free programmable software - Physical quantities / Output / Data logger / Charts / Calibration
-
Features • IP65 , rugged aluminum case, fit in variety harsh environment • Capable of temperature compensation. Linear adjustment temperature & humidity by computer, analog output or option RS-485 • Measure high accuracy Temp. & humidity, reaction quickly, the sensor can work well after temporary condensation, long term stable in high humidity environment • Process Temp. : up to 200°C, S.S. probe proof pressure : 10 bar, metal connector : installation repeatedly • Switch multifunction physical quantities:[%RH]、[°C]、[mbar]、[g/kg]、[g/m3]、[kj/kg] • Calibration physical quantities, measuring range, analog output, station, etc • Free calibration software : data logger / record 65535 datas / charts
-
Features • Dew point calibration, highly accuracy, 4 ... 20 mA and RS-485 output • Reduce insensitivity temperature zone, quickly response • Hysteresis compensation, resistance to moisture, extreme high and low humidity impact • EMC anti-interference, anti-condensation, low-temperature influence, long-term stability • Three thread (1/2″PT, 1/2″G, and 5/8″UNF) mode can be selected
-
Features
- MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package
- Stable firmware based on Linux
- 13 available input/output blocks
- Colour LCD display 3,5" TFT, with touchscreen
- Recording data with maximum speed 10Hz (ten samples per second)
- 2 or 4 GB internal data memory
- RS-485 (Modbus RTU), USB Host, Ethernet communication
- Wall mounted IP 65 case
-
Features
- MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package
- stable firmware based on Linux
- 27 available input/output modules
- 60 logical channels
- colour LCD display 3.5" TFT, with touchscreen
- recording data with maximum speed 10Hz (ten samples per second)
- 2 or 4 GB internal data memory
- RS-485 (Modbus RTU), USB Host, Ethernet communication
- panel, compact device in 96 x 96 mm case
-
Features
- MultiCon = Meter + Controller + Recorder + HMI + SCADA in one package
- stable firmware based on Linux
- 41 available input/output modules
- 90 logical channels
- colour LCD display 5.7" TFT, with touchscreen
- recording data with maximum speed 10Hz (ten samples per second)
- 2 or 4 GB internal data memory
- RS-485 (Modbus RTU), USB Host, Ethernet communication
- panel, compact device in 144 x 144 mm case
-
Features • Operator interface with color touch screen display, 3.5 “ • Up to 8 PID control loops • Cascade, ratio and valve PID controls • Profile programmer with ramps and retention; synchronous and asynchronous • Up to 200 Programs with 50 segments • 3 password protected user levels • Energy meter (kWh) • Configurable logic operations • Configurable math functions • Data Log with Real Time Clock • Batch Report management • Open format files (CSV) or encrypted for DataLog and production batches • Setting up custom pages • Management of active and historic alarms • Active and historical alarm management • USB for data export and parameter cloning • Control parameter advanced tuning • Configurable analogue and digital I/O signals • HMI/SCADA/PLC data exchange via Ethernet Modbus TCP • Message language selection
-
Features • Operator interface with color touch screen display, 7” • Up to 16 PID control loops • Cascade, ratio and valve PID controls • Profile programmer with ramps and retention; synchronous and asynchronous • Up to 250 Programs with 50 segments • 3 password protected user levels • Energy meter (kWh) • Configurable logic operations • Configurable math functions • Data Log with Real Time Clock • Batch Report management • Open format files (CSV) or encrypted for DataLog and production batches • Setting up custom pages • Active and historical alarm management • USB for data export and parameter cloning • Control parameter advanced tuning • Configurable analogue and digital I/O signals • HMI/SCADA/PLC data exchange via Ethernet Modbus TCP • Message language selection
-
Features • Multi-input and multi-range performance • Small instrument depths (62mm - 65mm) save space, thus securing a larger installation area. • SV setting: 3 points • PID Value: 3 types • 2-output heating and cooling control available (optional) • Total 32 steps Program available (optional) (1-4 pattern, 32-8 step) • RS-485 Interface available (optional) (Master/slave function, Modbus/Shimaden Protocol) • Heater break/heater loop alarm (optional) • A wide selection of additional functions (optional) is available to suit various needs. • Possible to switch off SV/PV value by key operation • Parameter mask (non-display) / lock (key lock) function
-
Features • Multi-input and multi-range performance • Small instrument depths (62mm - 65mm) save space, thus securing a larger installation area. • SV setting: 3 points • PID Value: 3 types • 2-output heating and cooling control available (optional) • Total 32 steps Program available (optional) (1-4 pattern, 32-8 step) • RS-485 Interface available (optional) (Master/slave function, Modbus/Shimaden Protocol) • Heater break/heater loop alarm (optional) • A wide selection of additional functions (optional) is available to suit various needs. • Possible to switch off SV/PV value by key operation • Parameter mask (non-display) / lock (key lock) function
-
Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac , continuous, digital insulated • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line. Protocol: GEFRAN CENCAL or MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
-
Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac , continuous, digital insulated • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line.Protocol: GEFRAN CENCAL or MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
-
Features • Universal input configurable from faceplate • Accuracy better than 0.2% f.s. under nominal conditions • Control output: relay, logic, Triac or continuous • Hot/cold function with selection of cooling fluid • 3 alarms with completely configurable function • Analog retransmission output • Up to 2 isolated digital inputs with configurable function • Isolated digital input with configurable function • Auxiliary input for CT (TA) (50mAac) • Heater break or probe short-circuit alarm • Self-tuning, Auto-tuning, Soft-start, bumpless Man/Auto function • Double set, set ramp, timed output function • Optically isolated RS485 serial line. Protocol: GEFRAN MODBUS RTU • Self-diagnosis • Rapid configuration from PC with Winstrum packet
-
Features • 2-channel controller (Basic type: 1-channel controller) • Independent 2-loop / Internal Cascade / 2-input operation control • High accuracy ± (0.1% FS + 1 digit) • High Sampling Cycle 0.1 sec. • High resolution 1/ 1000 °C display achieved *Only for R.T.D. input (scale: 0.000~30.000 °C) • Auto-Tuning PID / Expert PID / Self-Tuning PID • Multi-Setting of 10 Set Values • Independent Universal-Input • User Friendly Operation (Menu Driven: 4 Lines LCD Display) • Easy Setting & Maintenance via Infrared COM port on the front panel • Interface RS-232C/RS-485 (MODBUS / Shimaden) • The front dust/splash-proof IP66 • Universal Power Supply (100~240V AC ±10%) • Sensor power supply
-
Features • 3-channel controller, 3-channel input, 3-channel setting and simultaneous 3-channel display are possible • Accuracy: ± (0.3% FS + 1 digit) • Follow-up type PV input function • Follow-up type SV setting function • Remote/local and DI input function • Programmable 1 pattern with 9-step function • Included a new processing system, Expert PID, remarkably improved PID control efficiency; overshoot and undershoot are controlled effectively. • Interface RS232C/RS485
-
Features • 2-channel controller (Basic type: 1-channel controller) • Independent 2-loop / 2-input operation control • High accuracy ± (0.1% FS + 1 digit) • High Sampling Cycle 0.1 sec. • High resolution 1/ 1000 °C display achieved *Only for R.T.D. input (scale: 0.000~30.000 °C) • Programmable Max. 400 steps (400 steps x 1 pattern to 20 steps x 20 patterns) • Auto-Tuning PID / Expert PID • Max. 10 Zone PID control available • Independent Universal-Input • User Friendly Operation (Menu Driven: 4 Lines LCD Display) • Easy Setting & Maintenance via Infrared COM port on the front panel • Interface RS-232C/RS-485 (MODBUS / Shimaden) • The front dust/splash-proof IP66 • Universal Power Supply (100~240V AC ±10%) • Sensor power supply
-
Features • Operator interface with large LCD Display, customizable, with choice of colors • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even with power off • Preventive maintenance with energy counters (kWh) and load switching • 16 function block applications • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • Universal input configurable for thermocouples, resistance thermometers, linear inputs • Remote set point input • Relay, logic, isolated analog outputs • Up to two CT inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU • Removable faceplate for immediate replacement • Sampling time 60ms
-
Features • Operator interface with large LCD Display and three configurable bargraphs • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even withe power off • Preventive maintenance with energy counters (kWh) and load switching • 32 function block applications • 8 Math application blocks • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • 2 Universal inputs configurable for thermocouples, resistance thermometers, linear inputs • 1 linear analog input configurable for auxiliary functions • 2 PID control loops • 2 set point programmers (192 steps in 16 programs, or 12 programs with 16 fixed steps each) • Relay, logic, isolated analog outputs • Up to two TA inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU slave • RS485 serial communication in Modbus RTU master for reading/ writing information to Modbus slave devices • Ethernet Modbus TCP communication in Slave mode • Web server for browser access to web pages residing in the device, for monitoring and setting parameters • Bridge function for creation of Modbus RTU 485 sub-network • Weekly clock\calendar with RTC • Removable faceplate for immediate replacement • Accuracy 0,1%, sampling time 60 ms
-
Features
- Operator interface with large LCD Display, customizable, with choice of colors
- Scrolling diagnostics messages, configurable, in the selected language
- Easy, guided configuration, copy/paste parameters even with power off
- Preventive maintenance with energy counters (kWh) and load switching
- 16 function block applications
- Timer, setpoint and algorithm programmer for controlling motorized valves
- Advanced tuning of control parameters
- Different password levels
- Universal input configurable for thermocouples, resistance thermometers, linear inputs
- Remote setpoint input
- Relay, logic, isolated analog outputs
- Up to two CT inputs for interrupted load diagnostics
- RS485 serial communication in Modbus RTU
- Removable faceplate for immediate replacement
- Sampling time 60ms
-
Features • Operator interface with large LCD Display, customizable, with choice of colors • Scrolling diagnostics messages, configurable, in the selected language • Easy, guided configuration, copy/paste parameters even with power off • Preventive maintenance with energy counters (kWh) and load switching • 16 function block applications • Timer, set point and algorithm programmer for controlling motorized valves • Advanced tuning of control parameters • Different password levels • Universal input configurable for thermocouples, resistance thermometers, linear inputs • Remote set point input • Relay, logic, isolated analog outputs • Up to two CT inputs for interrupted load diagnostics • RS485 serial communication in Modbus RTU • Removable faceplate for immediate replacement • Sampling time 60ms